Four-unit fixed dental prostheses replacing the maxillary incisors supported by two narrow-diameter implants - a five-year case series.

Clin Oral Implants Res

Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.

Published: July 2017

Objectives: (1) To determine the survival rate of 10 four-unit fixed dental prostheses (FDPs) replacing the four maxillary incisors, supported by 20 narrow-diameter implants (NDIs), (2) to assess the incidence of mechanical and biological complications, and (3) to evaluate bone level changes longitudinally after final FDP insertion.

Materials And Methods: Ten patients (six women, four men), mean age 49.4 ± 12.6 years, were treated with a four-unit anterior maxillary FDP (six screw-retained; four cemented). Biological parameters, eventual technical complications, radiographic measurements, and study casts were assessed at 1 (baseline), 3, and 5 years after implant placement. A multilevel logistic regression test was performed on clinical parameters and bone level changes (significance level P < 0.05).

Results: The 5-year implant and FDP survival rate was 100%. Mean modified plaque index (mPI) values were 0.03 and 0.02 at 3 and 5 years, significantly lower when compared to mPI (0.11 ± 0.31) at 1 year. Mean modified sulcus bleeding index (mSBI) was 0.08, 0.08, and 0.15 over time. Probing depth (PD) values were 1.57, 1.64, and 2.03 mm. Statistically significant differences were found between 1 vs. 5 year (P = 0.0003) and 3 vs. 5 year (P = 0.001). Keratinized mucosa (3.65 mm) remained stable during observation period. DIB mean values were 2.01 ± 0.34, 2.13 ± 0.13, and 2.17 ± 0.38 mm. Patient satisfaction based on visual analog scale revealed favorable fulfillment of overall treatment and esthetic expectations.

Conclusions: Two NDIs supporting a four-unit FDP to replace the four missing maxillary incisors may be considered a predictable treatment modality.

Download full-text PDF

Source
http://dx.doi.org/10.1111/clr.12895DOI Listing

Publication Analysis

Top Keywords

four-unit fixed
8
fixed dental
8
dental prostheses
8
replacing maxillary
8
maxillary incisors
8
incisors supported
8
supported narrow-diameter
8
narrow-diameter implants
8
bone level
8
level changes
8

Similar Publications

Objectives:  The aim of this research is to evaluate/compare the use of traditional versus sleeve fixed partial denture (PD) designs made from different materials on supporting structures. The comparison included three- and four-unit PD cases.

Materials And Methods:  Four finite element models are used in the research.

View Article and Find Full Text PDF

Purpose: To inspect the impact of polyethylene fiber (Ribbond) on the long-span, 3D-printed, interim fixed dental prosthesis regarding fracture strength.

Materials And Methods: A stainless steel platform was fabricated to replicate the partial edentulism for a maxillary four-unit fixed dental prosthesis. The prosthesis was fabricated by a Formlabs SLA 3D printer.

View Article and Find Full Text PDF

The Accuracy of 3D-Printed Fixed Dental Restorations.

J Esthet Restor Dent

December 2024

Department of Prosthodontics, University Hospital Berlin Charité, Berlin, Germany.

Objective: The aim of this in vitro study was to evaluate the accuracy of resin-based fixed dental restorations, namely veneers, single crowns, and four-unit fixed partial dental prosthesis (FPDs), using two different 3D printing technologies and polymer-based materials.

Materials And Methods: A standard maxillary polyurethane jaw model containing prepared teeth was scanned using an intraoral scanner. The generated STL data were used to design the restorations virtually using CAD software.

View Article and Find Full Text PDF

Aim: This study aimed to evaluate the fracture resistance of implant-supported fixed partial prostheses fabricated from monolithic zirconia with different pontic framework designs and anchored in different bone-like simulation models of two different densities.

Materials And Methods: A total of 60 implants were anchored in two different bone simulation models of two different densities, namely, solid polyurethane foam blocks, 20 and 10 pounds per cubic foot (PCF) to construct implant-supported fixed partial dentures (FPDs), the pontic constructed to replace missing second premolar and first molar. Thirty models were constructed and then divided into two groups according to anchoring material D2 ( = 15) and D3 ( = 15).

View Article and Find Full Text PDF

Clinical and radiographic outcomes of implant-supported fixed prostheses with cantilever extension in anterior mandible: A retrospective study.

Clin Oral Implants Res

September 2024

Key Laboratory of Oral Biomedical Research of Zhejiang Province, Clinical Research Center for Oral Disease of Zhejiang Province, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Cancer Center of Zhejiang University, Hangzhou, China.

Objectives: The objective of this study is to analyze the clinical and radiographic outcomes of implant-supported fixed protheses with cantilever extensions (ISFPCs) in the partially edentulous anterior mandible.

Materials And Methods: Patients who received anterior mandible implant restoration between January 2016 and December 2021 were included. Patients with two, three, or four continuous missing teeth receiving adjacent implant supported single-unit crowns (ISSCs), ISFPCs, implant-supported fixed protheses without cantilever extensions (ISFPNs) were divided into groups: ISSC+ISSC, ISFPC, ISSC+ISFPC, three-unit ISFPN, ISFPC+ISFPC, or four-unit ISFPN, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!