Objectives: (1) To determine the survival rate of 10 four-unit fixed dental prostheses (FDPs) replacing the four maxillary incisors, supported by 20 narrow-diameter implants (NDIs), (2) to assess the incidence of mechanical and biological complications, and (3) to evaluate bone level changes longitudinally after final FDP insertion.
Materials And Methods: Ten patients (six women, four men), mean age 49.4 ± 12.6 years, were treated with a four-unit anterior maxillary FDP (six screw-retained; four cemented). Biological parameters, eventual technical complications, radiographic measurements, and study casts were assessed at 1 (baseline), 3, and 5 years after implant placement. A multilevel logistic regression test was performed on clinical parameters and bone level changes (significance level P < 0.05).
Results: The 5-year implant and FDP survival rate was 100%. Mean modified plaque index (mPI) values were 0.03 and 0.02 at 3 and 5 years, significantly lower when compared to mPI (0.11 ± 0.31) at 1 year. Mean modified sulcus bleeding index (mSBI) was 0.08, 0.08, and 0.15 over time. Probing depth (PD) values were 1.57, 1.64, and 2.03 mm. Statistically significant differences were found between 1 vs. 5 year (P = 0.0003) and 3 vs. 5 year (P = 0.001). Keratinized mucosa (3.65 mm) remained stable during observation period. DIB mean values were 2.01 ± 0.34, 2.13 ± 0.13, and 2.17 ± 0.38 mm. Patient satisfaction based on visual analog scale revealed favorable fulfillment of overall treatment and esthetic expectations.
Conclusions: Two NDIs supporting a four-unit FDP to replace the four missing maxillary incisors may be considered a predictable treatment modality.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/clr.12895 | DOI Listing |
Eur J Dent
December 2024
Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, Dar Al Uloom University, Riyadh, Saudi Arabia.
Objectives: The aim of this research is to evaluate/compare the use of traditional versus sleeve fixed partial denture (PD) designs made from different materials on supporting structures. The comparison included three- and four-unit PD cases.
Materials And Methods: Four finite element models are used in the research.
Purpose: To inspect the impact of polyethylene fiber (Ribbond) on the long-span, 3D-printed, interim fixed dental prosthesis regarding fracture strength.
Materials And Methods: A stainless steel platform was fabricated to replicate the partial edentulism for a maxillary four-unit fixed dental prosthesis. The prosthesis was fabricated by a Formlabs SLA 3D printer.
J Esthet Restor Dent
December 2024
Department of Prosthodontics, University Hospital Berlin Charité, Berlin, Germany.
Objective: The aim of this in vitro study was to evaluate the accuracy of resin-based fixed dental restorations, namely veneers, single crowns, and four-unit fixed partial dental prosthesis (FPDs), using two different 3D printing technologies and polymer-based materials.
Materials And Methods: A standard maxillary polyurethane jaw model containing prepared teeth was scanned using an intraoral scanner. The generated STL data were used to design the restorations virtually using CAD software.
J Contemp Dent Pract
July 2024
Fixed Prosthodontic Department, Faculty of Dentistry, Minia University, Minia, Egypt.
Aim: This study aimed to evaluate the fracture resistance of implant-supported fixed partial prostheses fabricated from monolithic zirconia with different pontic framework designs and anchored in different bone-like simulation models of two different densities.
Materials And Methods: A total of 60 implants were anchored in two different bone simulation models of two different densities, namely, solid polyurethane foam blocks, 20 and 10 pounds per cubic foot (PCF) to construct implant-supported fixed partial dentures (FPDs), the pontic constructed to replace missing second premolar and first molar. Thirty models were constructed and then divided into two groups according to anchoring material D2 ( = 15) and D3 ( = 15).
Clin Oral Implants Res
September 2024
Key Laboratory of Oral Biomedical Research of Zhejiang Province, Clinical Research Center for Oral Disease of Zhejiang Province, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Cancer Center of Zhejiang University, Hangzhou, China.
Objectives: The objective of this study is to analyze the clinical and radiographic outcomes of implant-supported fixed protheses with cantilever extensions (ISFPCs) in the partially edentulous anterior mandible.
Materials And Methods: Patients who received anterior mandible implant restoration between January 2016 and December 2021 were included. Patients with two, three, or four continuous missing teeth receiving adjacent implant supported single-unit crowns (ISSCs), ISFPCs, implant-supported fixed protheses without cantilever extensions (ISFPNs) were divided into groups: ISSC+ISSC, ISFPC, ISSC+ISFPC, three-unit ISFPN, ISFPC+ISFPC, or four-unit ISFPN, respectively.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!