A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

CO2 Cluster Ion Beam, an Alternative Projectile for Secondary Ion Mass Spectrometry. | LitMetric

CO2 Cluster Ion Beam, an Alternative Projectile for Secondary Ion Mass Spectrometry.

J Am Soc Mass Spectrom

Chemistry Department, Pennsylvania State University, University Park, PA, 16802, USA.

Published: September 2016

AI Article Synopsis

  • The use of argon-based gas cluster ion beams in SIMS (Secondary Ion Mass Spectrometry) enhances molecular depth profiling and 3D chemical imaging by reducing surface damage and maintaining better mass spectra quality.
  • Despite these benefits, challenges like low sensitivity and beam focusing in nanoscale bioimaging persist, which may be addressed by using CO2 as an alternative projectile.
  • Results show CO2 cluster projectiles perform comparably to argon, with improved imaging resolution and greater stability, allowing for more effective operation at lower pressures.

Article Abstract

The emergence of argon-based gas cluster ion beams for SIMS experiments opens new possibilities for molecular depth profiling and 3D chemical imaging. These beams generally leave less surface chemical damage and yield mass spectra with reduced fragmentation compared with smaller cluster projectiles. For nanoscale bioimaging applications, however, limited sensitivity due to low ionization probability and technical challenges of beam focusing remain problematic. The use of gas cluster ion beams based upon systems other than argon offer an opportunity to resolve these difficulties. Here we report on the prospects of employing CO2 as a simple alternative to argon. Ionization efficiency, chemical damage, sputter rate, and beam focus are investigated on model compounds using a series of CO2 and Ar cluster projectiles (cluster size 1000-5000) with the same mass. The results show that the two projectiles are very similar in each of these aspects. Computer simulations comparing the impact of Ar2000 and (CO2)2000 on an organic target also confirm that the CO2 molecules in the cluster projectile remain intact, acting as a single particle of m/z 44. The imaging resolution employing CO2 cluster projectiles is improved by more than a factor of two. The advantage of CO2 versus Ar is also related to the increased stability which, in addition, facilitates the operation of the gas cluster ion beams (GCIB) system at lower backing pressure. Graphical Abstract ᅟ.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5199235PMC
http://dx.doi.org/10.1007/s13361-016-1423-zDOI Listing

Publication Analysis

Top Keywords

cluster ion
16
co2 cluster
12
gas cluster
12
ion beams
12
cluster projectiles
12
cluster
8
chemical damage
8
employing co2
8
co2
6
ion
5