Model-based analysis of a dielectrophoretic microfluidic device for field-flow fractionation.

J Sep Sci

Department of Mechanical and Industrial Engineering, Concordia University, Montreal, Canada.

Published: August 2016

AI Article Synopsis

  • Developed a dynamic model to predict microparticle movements in microfluidic devices using dielectrophoresis for Hyperlayer field-flow fractionation.
  • The model uses finite-sized electrodes aligned on top and bottom walls of the microchannel, applying Laplace's equation for electric potential and Newton's second law for particle motion.
  • Key findings indicate that above a certain flow rate, microparticle radius does not affect levitation height, while microchannel depth, electrode spacing, and actuation voltage do impact the steady-state height.

Article Abstract

We present the development of a dynamic model for predicting the trajectory of microparticles in microfluidic devices, employing dielectrophoresis, for Hyperlayer field-flow fractionation. The electrode configuration is such that multiple finite-sized electrodes are located on the top and bottom walls of the microchannel; the electrodes on the walls are aligned with each other. The electric potential inside the microchannel is described using the Laplace equation while the microparticles' trajectory is described using equations based on Newton's second law. All equations are solved using finite difference method. The equations of motion account for forces including inertia, buoyancy, drag, gravity, virtual mass, and dielectrophoresis. The model is used for parametric study; the geometric parameters analyzed include microparticle radius, microchannel depth, and electrode/spacing lengths while volumetric flow rate and actuation voltage are the two operating parameters considered in the study. The trajectory of microparticles is composed of transient and steady state phases; the trajectory is influenced by all parameters. Microparticle radius and volumetric flow rate, above the threshold, do not influence the steady state levitation height; microparticle levitation is not possible below the threshold of the volumetric flow rate. Microchannel depth, electrode/spacing lengths, and actuation voltage influence the steady-state levitation height.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.201600350DOI Listing

Publication Analysis

Top Keywords

volumetric flow
12
flow rate
12
field-flow fractionation
8
trajectory microparticles
8
microparticle radius
8
microchannel depth
8
depth electrode/spacing
8
electrode/spacing lengths
8
actuation voltage
8
steady state
8

Similar Publications

Purpose: This study investigates the capabilities of ultrasonography (US) in determing the stage of orbital inflammation in patients with granulomatosis with polyangiitis (GPA).

Material And Methods: The study included 24 patients (8 men and 16 women) with diffuse orbital tissue involvement in GPA. Group 1 (active stage) included nine patients, while group 2 (inactive stage) consisted of 18 patients.

View Article and Find Full Text PDF

Adsorption of Cr(VI) Using Organoclay/Alginate Hydrogel Beads and Their Application to Tannery Effluent.

Gels

November 2024

Departamento de Ingeniería Química, Universidad Nacional de Colombia Sede Manizales, Campus La Nubia, km 9 vía al Aeropuerto, Manizales 170003, Colombia.

The tanning industry is among the most environmentally harmful activities globally due to the pollution of lakes and rivers from its effluents. Hexavalent chromium, a metal in tannery effluents, has adverse effects on human health and ecosystems, requiring the development of removal techniques. This study assessed the efficacy of organobentonite/alginate hydrogel beads in removing Cr(VI) from a fixed-bed adsorption column system.

View Article and Find Full Text PDF

Background And Purpose: Idiopathic normal pressure hydrocephalus (iNPH) is a cerebrospinal fluid (CSF) dynamics disorder as evidenced by the delayed ascent of radiotracers over the cerebral convexity on radionuclide cisternography. However, the exact mechanism causing this disruption remains unclear. Elucidating the pathophysiology of iNPH is crucial, as it is a treatable cause of dementia.

View Article and Find Full Text PDF

The hemodynamic responses to enhanced external counterpulsation therapy in post-PCI patients with a multi-dimension 0/1D-3D model.

J Biomech

December 2024

Department of Cardiology, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen, Guangdong 518033, China; Guangdong Innovative Engineering and Technology Research Center for Assisted Circulation, Sun Yat-sen University, Shenzhen, Guangdong 518033, China. Electronic address:

Enhanced external counterpulsation (EECP) is widely utilized in rehabilitating patients after percutaneous coronary intervention (PCI) and has demonstrated efficacy in promoting cardiovascular function recovery. Although the precise mechanisms of the therapeutic effects remain elusive, it is widely postulated that the improvement of biomechanical environment induced by EECP plays a critical role. This study aimed to unravel the underlying mechanism through a numerical investigation of the in-stent biomechanical environment during EECP using an advanced multi-dimensional 0/1D-3D coupled model.

View Article and Find Full Text PDF

We present a versatile flow-through tube passive sampling device (TPS), with a controllable feedwater volumetric flow, that can be calibrated against the feedwater load of organic micropollutants (OMPs). This semipassive approach has the advantage of a determinable water load feeding the sampling device. The design of the TPS allows for new sampling scenarios in closed piping while providing stable and controlled sampling conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!