Background: Cyanoacrylate(CA)-based tissue adhesives, although not widely used, are a feasible option to fix a mesh during abdominal hernia repair, due to its fast action and great bond strength. Their main disadvantage, toxicity, can be mitigated by increasing the length of their alkyl chain. The objective was to assess the in vitro cytotoxicity and in vivo biocompatibility in hernia repair of CAs currently used in clinical practice (Glubran(n-butyl) and Ifabond(n-hexyl)) and a longer-chain CA (OCA(n-octyl)), that has never been used in the medical field.

Methods: Formaldehyde release and cytotoxicity of unpolymerized(UCAs) and polymerized CAs(PCAs) were evaluated by macroscopic visual assessment, flow cytometry and Alamar Blue assays. In the preclinical evaluation, partial defects were created in the rabbit abdominal wall and repaired by fixing polypropylene prostheses using the CAs. At 14 days post-surgery, animals were euthanized for morphology, macrophage response and cell damage analyses.

Results: Formaldehyde release was lower as the molecular weight of the monomer increased. The longest side-chain CA(OCA) showed the highest cytotoxicity in the UCA condition. However, after polymerization, was the one that showed better behavior on most occasions. In vivo, all CAs promoted optimal mesh fixation without displacements or detachments. Seroma was evident with the use of Glubran, (four of six animals: 4/6) and Ifabond (2/6), but it was reduced with the use of OCA (1/6). Significantly greater macrophage responses were observed in groups where Glubran and Ifabond were used vs. sutures and OCA. TUNEL-positive cells were significantly higher in the Glubran and OCA groups vs. the suture group.

Conclusions: Although mild formaldehyde release occurred, OCA was the most cytotoxic during polymerization but the least once cured. The CAs promoted proper mesh fixation and have potential to replace traditional suturing techniques in hernia repair; the CAs exhibited good tissue integration and effective short-term biocompatibility, with the slightest seroma and macrophage response induced by OCA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4913938PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0157920PLOS

Publication Analysis

Top Keywords

hernia repair
16
formaldehyde release
12
tissue adhesives
8
vivo biocompatibility
8
abdominal hernia
8
repair cas
8
macrophage response
8
cas promoted
8
mesh fixation
8
cas
5

Similar Publications

Background: Transabdominal pre-peritoneal inguinal hernia repair using the da Vinci Single-Port robot (SP-TAPP) is currently performed in few centers. We aimed to define the learning curve for SP-TAPP by analyzing operative times.

Methods: The operative times of 122 SP-TAPP performed between 2019 and 2024 were retrospectively analyzed.

View Article and Find Full Text PDF

Comparative analysis of efficacy and quality of life between totally extraperitoneal sublay and intraperitoneal onlay mesh repair for ventral hernia.

Sci Rep

January 2025

Department of General Surgery, Shaoxing Central Hospital (The Central Affiliated Hospital, Shaoxing University), Shaoxing, 312030, Zhejiang Province, China.

Ventral hernias pose a prevalent challenge in abdominal wall surgery, with ongoing advancements in repair techniques designed to enhance patient outcomes. This study evaluates the efficacy, safety, and socio-economic impact of Totally Extraperitoneal Sublay Repair (TES) versus Laparoscopic Intraperitoneal Onlay Mesh Repair (IPOM) for small to medium-sized ventral hernias, with a particular focus on postoperative quality of life and patient satisfaction. A retrospective cohort study was conducted, encompassing 125 patients who underwent ventral hernia repair between May 2018 and November 2023.

View Article and Find Full Text PDF

Production and Characterization of Oil-Loaded, Semi-Resorbable, Tri-Layered Hernia Mesh.

Polymers (Basel)

January 2025

Institute of Graduate Studies, Bioengineering Division, Tokat Gaziosmanpaşa University, 60250 Tokat, Türkiye.

Hernia repair is the most common surgical operation applied worldwide. Mesh prostheses are used to support weakened or damaged tissue to decrease the risk of hernia recurrence. However, the patches currently used in clinic applications have significant short-term and long-term risks.

View Article and Find Full Text PDF

Incisional ventral hernia repair remains a challenging surgery for abdominal wall surgeons. We report the results at 48 months post-surgery regarding open ventral hernia repair (OVHR), analyzing the recurrence rate and incidence of chronic pain. This was a retrospective, observational study of 111 consecutive patients who underwent OVHR.

View Article and Find Full Text PDF

To optimize the efficacy of analgesia for patients receiving laparoscopic inguinal hernia repair, peri-operative pain neuroscience education (PNE) as a pain-specific cognitive therapy was incorporated into multi-modal analgesia. A randomized controlled trial was conducted to compare conventional analgesia (group CA) and the addition of pain neuroscience education into it (group PNE) in patients receiving laparoscopic inguinal hernia repair. Characteristics of peri-operative pain was evaluated with Douleur Neuropathique 4 questionnaire (DN-4), central sensitization inventory (CSI), pain catastrophizing scale (PCS) post-operatively and pressure pain threshold.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!