A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Stable (18) O-labeling method for stercobilin and other bilins for metabolomics. | LitMetric

Stable (18) O-labeling method for stercobilin and other bilins for metabolomics.

Rapid Commun Mass Spectrom

Department of Chemistry, Natural Sciences Complex, University at Buffalo, Buffalo, NY, 14260-3000, USA.

Published: July 2016

Rationale: Bilin tetrapyrroles including stercobilin are unique to mammalian waste; they have been used as markers of source water contamination and may have important diagnostic value in human health conditions. Unfortunately, commercial isotopomers for bilins are not available. Thus, there is a need for isotopomer standards of stercobilin and other bilins for quantification in environmental and clinical diagnostic applications.

Methods: A procedure is described here using H2 (18) O to label the carboxylic acid groups of bilin tetrapyrroles. Reaction conditions as a function of temperature and reagent volume were found to produce a mixture of isotopomers, as assessed by electrospray ionization and Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS). Stability as a function of storage time and temperature and in conjunction with solid-phase extraction (SPE) was assessed.

Results: The highest labeling efficiency was achieved at 70 °C for 8 h, while a stable ratio of the isotopmers could be produced at 60 °C for 4 h. The stability of the isotopic distribution was maintained under storage (room temperature or frozen) for 20 days. It was also stable throughout SPE. The high mass accuracy and resolving power of FTICRMS enables clear distinction between (18) O-labeled bilins from other unlabeled bilins present, avoiding a potential interference in quantitation.

Conclusions: A procedure was developed to label bilins with (18) O. The final ratio of the (18) O-labeled bilin isotopomers was reproducible and highly stable for at least 20 days under storage. This ratio was not changed in any statistically significant way even after SPE. Thus a reliable method for producing stable isotopomer ratios for bilins has been achieved. Copyright © 2016 John Wiley & Sons, Ltd.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4916856PMC
http://dx.doi.org/10.1002/rcm.7580DOI Listing

Publication Analysis

Top Keywords

stercobilin bilins
8
bilin tetrapyrroles
8
bilins
7
stable
5
stable o-labeling
4
o-labeling method
4
method stercobilin
4
bilins metabolomics
4
metabolomics rationale
4
rationale bilin
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!