A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Acute toxicity when concentration varies with time: A case study with carbon monoxide inhalation by rats. | LitMetric

Exposure to time-varying concentrations of toxic compounds is the norm in both occupational settings and daily human life, but little has been done to investigate the impact of variations in concentration on toxic outcomes; this case study with carbon monoxide helps fill that gap. Median acute lethality of 10-, 20-, 40-, and 60-min continuous exposures of rats to carbon monoxide was well described by the toxic load model (k = C(n) × t; k is constant, C = test concentration, n = toxic load exponent, and t = exposure duration) with n = 1.74. Dose response-relationships for 1-h exposures including a recovery period between 10- or 20-min pulses showed greater similarity (in both median lethality and steepness of dose-response curve) to continuous exposures with equivalent pulse duration and concentration, rather than a 60-min exposure with equivalent time-weighted average concentrations or toxic load. When pulses were of unequal concentration (3:1 ratio), only the high concentration pulse contributed to lethality. These findings show that fluctuations or interruptions in exposure over a short time scale (60 min or less) can have a substantial impact on outcomes (when n > 1), and thus high-resolution monitoring data are needed to aid interpretation of resulting outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.yrtph.2016.06.014DOI Listing

Publication Analysis

Top Keywords

carbon monoxide
12
case study
8
study carbon
8
concentrations toxic
8
continuous exposures
8
toxic load
8
concentration
6
acute toxicity
4
toxicity concentration
4
concentration varies
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!