A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Optimisation for assay of fluorescein diacetate hydrolytic activity as a sensitive tool to evaluate impacts of pollutants and nutrients on microbial activity in coastal sediments. | LitMetric

Fluorescein diacetate (FDA) assay has been widely applied in coastal research to quantify microbial activity in sediments. However, the present FDA assay procedures embodied in sediment studies potentially include operational errors since the protocol was established for studies of terrestrial soil. In the present study, we optimised the procedure of FDA assay using sandy and cohesive sediments to improve experiential sensitivity and reproducibility. The optimised method describes quantitative measurement of the fluorescein produced when 1.0g of fresh sediment is incubated with 50mM phosphate buffer solution (pH: 7.3) and glass beads (2g) at 35°C for 1h under a rotation of 50rpm. The covariation coefficient of the optimised method ranged from 1.9% to 3.8% and the method sensitivity ranged from 0.25 to 1.57. The improved protocol provides a more reliable measurement of the FDA hydrolysis rate over a wide range of sediments compared to the original method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.marpolbul.2016.06.031DOI Listing

Publication Analysis

Top Keywords

fda assay
12
fluorescein diacetate
8
microbial activity
8
optimised method
8
optimisation assay
4
assay fluorescein
4
diacetate hydrolytic
4
hydrolytic activity
4
activity sensitive
4
sensitive tool
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!