How to deal with atrial septal defect closure from right internal jugular vein: Role of venous-arterial circuit for sizing and over-the-wire device implantation.

Catheter Cardiovasc Interv

Department of Congenital Cardiology and Cardiac Surgery, Policlinico San Donato IRCCS, via Morandi 30, San Donato Milanese, Milan, 20097, Italy.

Published: January 2017

Secundum atrial septum defect (ASD) is the most common congenital heart disease. It is usually treated by a transcatheter approach using a femoral venous access. In case of bilateral femoral vein occlusion, the internal jugular venous approach for ASD closure is an option, in particular in cases where ASD balloon occlusion test and sizing is needed. Here, we report on a new technique for ASD closure using a venous-arterial circuit from the right internal jugular vein to the femoral artery. Two patients (females, 4 and 10 years of age) had occlusion of both femoral veins because of a previous history of pulmonary atresia and intact ventricular septum, for which they underwent percutaneous radiofrequency perforation and balloon angioplasty. These subjects needed balloon occlusion test of a residual ASD to size the hole and to check for hemodynamic suitability to ASD closure. After performing a venous-arterial circuit, a 24 mm St Jude ASD sizing balloon catheter was advanced over the circuit and the defect closed for 15 min to check hemodynamics and size the defect. ASD was closed is hemodinamically suitable. This technique was safe and reliable. © 2016 Wiley Periodicals, Inc.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.26621DOI Listing

Publication Analysis

Top Keywords

internal jugular
12
venous-arterial circuit
12
asd closure
12
jugular vein
8
asd
8
defect asd
8
balloon occlusion
8
occlusion test
8
deal atrial
4
atrial septal
4

Similar Publications

To describe the distribution of jugular bulb position and pneumatization of posterior lip of internal auditory meatus (IAM) in patients with vestibular schwannoma (VS). This retrospective study included 43 patients who had a thin slice (< 2 mm) CT temporal bone for preoperative planning of retrosigmoid approach for excision of VS between March 2011 and March 2021. On computed tomography (CT), high riding jugular bulb was defined by its relationship to IAM and correlated with type of jugular bulb according to Manjila et al.

View Article and Find Full Text PDF

Mediastinal mass syndrome represents a major threat to respiratory and cardiovascular integrity, with difficult evidence-based risk stratification for interdisciplinary management. We conducted a narrative review concerning risk stratification and difficult airway management of patients presenting with a large mediastinal mass. This is supplemented by a case report illustrating our individual approach for a patient presenting with a subtotal tracheal stenosis due to a large cyst of the thyroid gland.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!