Subjective Comfort and Physiology with Modern Contact Lens Care Products.

Optom Vis Sci

*OD, PhD, FAAO †BSc(Hons), MCOptom, FAAO ‡PhD, FCOptom, FAAO §PhD, MCOptom, FAAO ∥BSc(Hons), PhD, MCOptom, FAAO **PhD, Dipl Ing (AO), FAAO ††OD, MPH, PhD, FAAO The Ocular Surface Institute, College of Optometry, University of Houston, Texas (DAB, JHM); Johnson & Johnson Vision Care, Inc., Jacksonville, Florida (SBH-C); Centre for Contact Lens Research, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada (LWJ, MMS); Eurolens Research, Faculty of Life Sciences, University of Manchester, United Kingdom (CM-C, PBM); and School of Optometry, University of Alabama at Birmingham, Alabama (JJN).

Published: August 2016

Purpose: To compare subjective comfort and ocular physiology with three multipurpose solutions (MPSs) to that of a peroxide-based system with three different soft contact lens materials.

Methods: Habitual soft contact lens wearers (n = 236) were enrolled at three sites and completed a washout period with no contact lens solution for ≥4 days. Subjects were randomly assigned to one of three lens types: etafilcon A, galyfilcon A, or senofilcon A. A new lens of the assigned type was worn for 10 to 14 days each while using one of four care solutions, in random order (A-polyaminopropyl biguanide + polyquaternium, B-POLYQUAD + Aldox, C-alexidine + polyquaternium-1, and D-hydrogen peroxide) with a washout period (≥4 days) between each solution. After each care solution, biomicroscopy was performed and subjective comfort was assessed using the Contact Lens User Experience (CLUE) questionnaire and other instruments including comfortable wear time (CWT). Linear mixed models were used for analysis. Comfort and biomicroscopy signs with each MPS were compared to that of the peroxide solution.

Results: Subjective CLUE Comfort score across all lens types with each MPS was not significantly different than with the peroxide solution (p = 0.98). There were no differences in CWT between each MPS and the peroxide solution for any lens type (range of differences: -0.8 to 0.8 h; all p ≥ 0.13). Six MPS/material combinations had no clinically meaningful change in corneal staining versus peroxide (<0.5 units); three combinations could increase staining by up to 0.57 units. Staining was
Conclusions: Comparable levels of comfort were found between the latest generation of MPSs compared to peroxide disinfection. Three MPS/material combinations tested could result in increased corneal staining of up to 0.57 units versus a peroxide solution. Overall, these data suggest the care systems investigated are generally appropriate for use with the contact lenses tested.

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000000901DOI Listing

Publication Analysis

Top Keywords

contact lens
20
subjective comfort
12
lens
9
soft contact
8
washout period
8
≥4 days
8
lens types
8
mps peroxide
8
peroxide solution
8
contact
5

Similar Publications

Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.

Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.

View Article and Find Full Text PDF

Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.

Ophthalmic Physiol Opt

January 2025

Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.

Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.

View Article and Find Full Text PDF

Perovskite-Based Smart Eyeglasses as Noncontact Human-Computer Interaction.

Adv Mater

January 2025

Key Laboratory of Green Printing, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences (ICCAS), Beijing Engineering Research Center of Nanomaterials for Green Printing Technology, Beijing National Laboratory for Molecular Sciences (BNLMS), Beijing, 100080, P. R. China.

More than 70% of human information comes from vision. The eye is one of the most attractive sensing sites to collect biological parameters. However, it is urgent to develop a cost-effective and easy-to-use approach to monitor eyeball information in a minimally invasive way instead of current smart contact lenses or camera-based eyeglasses.

View Article and Find Full Text PDF

Importance: For myopia control to be beneficial, it would be important that the benefit of treatment (slowed eye growth) is not lost because of faster than normal growth (rebound) after discontinuing treatment.

Objective: To determine whether there is a loss of treatment effect (rebound) after discontinuing soft multifocal contact lenses in children with myopia.

Design, Setting, And Participants: The Bifocal Lenses in Nearsighted Kids 2 (BLINK2) cohort study involved children with myopia (aged 11-17 years at BLINK2 baseline) who completed the BLINK Study randomized clinical trial.

View Article and Find Full Text PDF

Aim: To report the clinical and therapeutic particularities of pediatric keratoconus (KC).

Methods: Retrospective study focusing on patients aged less than 18 years, presenting with KC and followed in a tertiary reference center in Sfax, Tunisia.

Results: Our study involved 38 eyes of 20 children.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!