Background: Four-dimensional computed tomography is being used increasingly for localization of abnormal glands in primary hyperparathyroidism. We hypothesized that compared with traditional 4-phase imaging, 2-phase imaging would halve the radiation dose without compromising parathyroid localization and clinical outcomes.
Methods: A transition from 4-phase to 2-phase imaging was instituted between 2009 and 2010. A pre-post analysis was performed on patients undergoing operative treatment with a parathyroid protocol computed tomography, and relevant data were correlated with operative findings. Sensitivity, positive predictive value, technical success, and cure rates were calculated. The Fisher exact test or χ(2) test assessed the significance of 2-phase and 4-phase imaging and operative findings.
Results: Twenty-seven patients had traditional four-dimensional computed tomography and 35 had modified 2-phase computed tomography. Effective radiation doses were 6.8 mSy for 2-phase and 14 mSv for 4-phase. Four-phase computed tomography had a sensitivity and positive predictive value of 93% and 96%, respectively. Two-phase computed tomography had a comparable sensitivity and positive predictive value of 97% and 94%, respectively. Eight patients with discordant imaging had an average parathyroid weight of 240 g compared with 1,300 g for all patients. Technical surgical success (90% for 4-phase computed tomography versus 91% 2-phase computed tomography) and normocalcemia rates at 6 months (88% for both) did not differ between computed tomography protocols. Computed tomography correctly predicted multiglandular disease and localization for reoperations in 88% and 90% of cases, respectively, with no difference by computed tomography protocol.
Conclusion: With regard to surgical outcomes and localization, 2-phase parathyroid computed tomography is equivalent to 4-phase for parathyroid localization, including small adenomas, reoperative cases, and multiglandular disease. Two-phase parathyroid computed tomography for operative planning should be considered to avoid unnecessary radiation exposure.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4975639 | PMC |
http://dx.doi.org/10.1016/j.surg.2016.04.016 | DOI Listing |
Eur J Trauma Emerg Surg
January 2025
Department of Trauma and Orthopedic Surgery, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany.
Background: Rib and sternum fractures are common injuries associated with cardiopulmonary resuscitation (CPR). The fracture mechanism is either direct by application of force on sternum and anterior ribs or indirect by bending through compression of the thorax. The aim of this study was to determine morphologies of rib fractures after CPR and to reevaluate prior findings on fracture localisation, type and degree of dislocation.
View Article and Find Full Text PDFJ Periodontal Res
January 2025
Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
Aim: Ultrasonography (US) has shown accuracy in imaging healthy periodontium. This study aims to evaluate the feasibility and accuracy of US for estimating dimensions of inflamed periodontium induced by ligature and bacteria.
Methods: Periodontal tissues of maxillary as well as mandibular premolars and molars in six female mini pigs were treated with ligature and three strains of bacteria for 4-10 weeks.
BMC Oral Health
January 2025
Department of Conservative Dentistry, College of Dentistry, Kyung Hee University, 26-6, Kyungheedae-ro, Dongdaemun-gu, Seoul, 02453, Republic of Korea.
Background: This study aims to compare design, phase transformation behavior, and torsional resistance of the ProGlider (PG) and ProTaper ultimate slider (PUS) and to compare the performance of two files in the glide-path preparation of a double-curved artificial canal.
Methods: Scanning electron microscopy, micro-computed tomography, and differential scanning calorimetry were used to characterize the samples. A torsional resistance test was performed to obtain ultimate strength and distortion angle.
Deep learning (DL) methods have demonstrated remarkable effectiveness in assisting with lung cancer risk prediction tasks using computed tomography (CT) scans. However, the lack of comprehensive comparison and validation of state-of-the-art (SOTA) models in practical settings limits their clinical application. This study aims to review and analyze current SOTA deep learning models for lung cancer risk prediction (malignant-benign classification).
View Article and Find Full Text PDFInt J Oral Maxillofac Surg
January 2025
Stomatological Hospital of Chongqing Medical University, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China; Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China. Electronic address:
The retrospective study aimed to compare the space-maintaining effects of sticky bone (bone graft matrix enriched with injectable platelet-rich fibrin) and titanium mesh for bone augmentation in the aesthetic zone. Patients who underwent single implant placement and had type 2/4 alveolar bone defects (buccal bone wall loss is >50% of the expected implant length) were screened for inclusion in this study. The labial bone plate width was measured at 1, 3, and 5 mm below the apical implant platform on cone beam computed tomography images taken immediately and 6 months after surgery.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!