Persistence of Severe Pulmonary Hypertension After Transcatheter Aortic Valve Replacement: Incidence and Prognostic Impact.

Circ Cardiovasc Interv

From the Department of Cardiology, IRCCS Pol San Donato, San Donato Milanese, Milan, Italy (L.T., R.M., M.A., N.B., F.B.); Interventional Cardiology Unit, Department of Cardiology, San Raffaele Hospital and EMO-GVM Centro Cuore Columbus, Milan, Italy (A.L., A.C.); Department of Cardiology, Niguarda Ca Granda Hospital, Milan, Italy (F.D.M., S.K.); Cardiothoracic and Vascular Department, Azienda Ospedaliero-Universitaria Pisana, Pisa, Italy (M.D.C., A.S.P.); Cardiothoracic Department, Spedali Civili, Brescia, Italy (C.F., F.E.); Department of Cardiology, Ferrarotto Hospital, Catania, Italy (M.B., C.T.); Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy (G.B.Z.); and Department of AngioCardioNeurology, IRCCS Neurome, Pozzilli, Italy (G.B.Z.).

Published: June 2016

Background: Severe pulmonary hypertension (PH) is considered to negatively affect the outcome after transcatheter aortic valve replacement. However, a clear understanding of the pattern, evolution, and clinical impact of different grades of PH in this setting is lacking.

Methods And Results: A total of 990 consecutive patients were enrolled in 6 high-volume centers and analyzed as follows: group 1, systolic pulmonary artery pressure (sPAP) <40 mm Hg (346 patients; 35%); group 2, sPAP 40 to 60 mm Hg (426 patients; 43%); and group 3, sPAP >60 mm Hg (218 patients; 22%). At 1 month, mortality rate did not differ across the groups. When compared with groups 1 and 2, patients in group 3 had a higher-rate of New York Heart Association 3 to 4 (26% versus 12% and 10%), and a higher-rate of hospitalization for heart failure (7% versus 3% and 3%). At 1 year, when compared with patients in group 1, patients in group 2 and 3 had both a higher overall mortality (hazard ratio [HR], 1.5 [1.3-3.2]; P=0.01 and HR, 2.3 [1.8-2.8]; P=0.001) and a higher cardiac mortality (HR, 1.3 [1.1-2.1]; P=0.01 and HR, 1.7 [1.3-2.5]; P=0.002). After 1 month, the sPAP decreased ≥15 mm Hg in 32% and 35% of the patients in groups 2 and 3. Baseline sPAP >60 mm Hg (HR, 1.6 [1.1-2.3]; P=0.03) and, in a larger extent, a persistent severe PH after 1 month (HR, 2.4 [1.5-2.8]; P=0.004), independently predicted 1-year mortality, whereas the 1-month reduction of the sPAP did not.

Conclusions: The persistence of severe PH after transcatheter aortic valve replacement is a stronger predictor of 1-year mortality than baseline severe PH. The early reduction of sPAP is not associated with a reduced mortality. The benefit of transcatheter aortic valve replacement in terms of quality of life is substantial in patients with and without a reduction of sPAP at early follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCINTERVENTIONS.115.003563DOI Listing

Publication Analysis

Top Keywords

transcatheter aortic
16
aortic valve
16
valve replacement
16
patients group
12
reduction spap
12
persistence severe
8
severe pulmonary
8
pulmonary hypertension
8
1-year mortality
8
patients
7

Similar Publications

Background: Recent studies revealed an association between small kidney volume and progression of kidney dysfunction in particular settings such as kidney transplantation and transcatheter aortic valve implantation. We hypothesized that kidney volume was associated with the incidence of kidney-related adverse outcomes such as worsening renal function (WRF) in patients with acute heart failure (AHF).

Methods: This study was a single-center retrospective cohort study.

View Article and Find Full Text PDF

Re-sheathing failure with Navitor during transcatheter aortic valve implantation: a case report.

Eur Heart J Case Rep

January 2025

The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.

Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.

Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.

View Article and Find Full Text PDF

Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!