Introduction: SCFE occurs in 10 per 100,000 in some regions of the United States with the incidence continuing to increase. Percutaneous screw fixation is a well-accepted treatment for this disorder for over 20 years but management of complications is not well elucidated in the literature.

Case Report: We describe a case where a traumatic unstable SCFE that was initially treated with closed reduction and fixation with a single transphyseal screw went on to hardware failure with recurrence of the deformity. The complication was successfully treated with closed reduction and re-cannulating the fractured screw within the epiphysis and extracting it using a conical extraction screw commonly referred to as an "easy out." Three trans physeal screws were then placed for improved fixation strength. Follow-up at 9 months demonstrates a fused physis and no signs of avascular necrosis of the femoral head.

Conclusion: Percutaneous management of SCFE screw breakage is possible utilizing specialized instruments and a precise and gentle manipulation preventing the need for more invasive treatments with their obligatory potential complications profile.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4722563PMC
http://dx.doi.org/10.13107/jocr.2250-0685.144DOI Listing

Publication Analysis

Top Keywords

treated closed
8
closed reduction
8
screw
6
management cannulated
4
cannulated screw
4
screw failure
4
failure recurrent
4
scfe
4
recurrent scfe
4
scfe displacement
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!