The aim of this EP Wire was to assess the management, indications, and techniques for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) device replacement in Europe. A total of 24 centres in 14 European countries completed the questionnaire. All centres were members of the European Heart Rhythm Association Electrophysiology Research Network. Replacement procedures were performed by electrophysiologists in 52% of the centres, by cardiologists in 33%, and both in the remaining centres. In the majority of centres, the procedures were performed during a short hospitalization (<2 days; 61.2%), or on an outpatient basis (28%). The overwhelming majority of centres reported that they replaced ICDs at the end of battery life. Only in a small subset (<10%) of patients with ICD for primary prevention and without ventricular tachycardia (VT) since implantation, ICD was not replaced. In inherited primary arrhythmia syndromes, 80% of the centres always replaced the ICD at the end of battery life. After VT ablation, only few centres (9%) explanted or downgraded the device that was previously implanted for secondary prevention, but only in those patients without new VT episodes. Patient's life expectancy <1 year was the most commonly reported reason (61%) to downgrade from a CRT-D to a CRT-P device. While warfarin therapy was continued in 47% of the centres, non-vitamin K oral anticoagulants were discontinued without bridging 24 h prior to replacement procedures in 60%. Finally, in 65% of the centres, VT induction and shock testing during ICD and CRT-D replacement were performed only in the case of leads with a warning or with borderline measurements. This survey provides a snapshot of the perioperative management, indications, and techniques of ICD and CRT device replacement in Europe. It demonstrates some variations between participating centres, probably related to local policies and to the heterogeneity of the ICD population.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/euw157DOI Listing

Publication Analysis

Top Keywords

implantable cardioverter
8
cardiac resynchronization
8
resynchronization therapy
8
european heart
8
heart rhythm
8
rhythm association
8
procedures performed
8
centres
5
replacement implantable
4
cardioverter defibrillators
4

Similar Publications

Objectives: This systematic review aimed to review existing evidence to evaluate the effects of physical cardiac rehabilitation on cardio-pulmonary outcomes in the patients with hypertrophic cardiomyopathy (HCM).

Methods: We conducted a systematic search of the databases PubMed, Web of Science, Embase, Scopus, and Google Scholar. The initial search led to 1222 citations after removing duplicate results.

View Article and Find Full Text PDF

The European Society of Cardiology (ESC) has updated its guidelines on cardiac pacing and cardiac resynchronisation. As the majority are class II recommendations (61%) and based on expert opinion (59%), a critical appraisal for the Dutch situation was warranted. A working group has been established, consisting of specialists in cardiology, cardiothoracic surgery, geriatrics, allied professionals in cardiac pacing, and patient organisations with support from the Knowledge Institute of the Dutch Association of Medical Specialists.

View Article and Find Full Text PDF

Cardiovascular imaging in children with cardiac implantable electronic devices.

Pediatr Radiol

January 2025

Department of Cardiology, Boston Children's Hospital and Department of Pediatrics, Harvard Medical School, Boston, MA, 02115, USA.

The number of children with cardiac implantable electronic devices (CIEDs) is increasing at a time of rapid growth in cardiac magnetic resonance (MR) and cardiac computed tomography (CT) utilization. The presence of CIEDs poses challenges with respect to imaging safety and quality. A thoughtful approach to cardiovascular imaging in patients with CIEDs begins with an awareness of the clinical indications to determine the most appropriate imaging modality.

View Article and Find Full Text PDF

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an alternative to traditional ICDs. The PRAETORIAN score, based on chest radiographs, has been validated to predict the probability of successful S-ICD defibrillation testing by assessing factors like fat thickness between the coil and sternum and generator placement.

Objective: This study evaluated the correlation between the PRAETORIAN score and clinical characteristics, as well as implantation variables.

View Article and Find Full Text PDF

Studies have demonstrated overall prognostic benefits of ICD implantation in patients at increased risk of sudden cardiac death. However, results are inconsistent in certain subgroups. This study aims to evaluate the prognostic implications of comorbidities on ICD outcomes and compare trends in patient selection and outcomes over a decade-long inclusion period.

View Article and Find Full Text PDF