Multiplex bead-based flow cytometry is an attractive way for simultaneous, rapid and cost-effective analysis of multiple analytes in a single sample. Previously, we developed various bead-based assays using non-magnetic beads coated with Staphylococcus aureus and Streptococcus pneumoniae antigens for the detection of antibodies. Here, we compared the performance of the assay using non-magnetic beads with one based on the newly developed magnetic beads. We optimized the magnetic beads' coupling procedure and antibody detection assays for S. aureus and S. pneumoniae antigens and we measured IgG in human pooled serum against a series of S. aureus and S. pneumoniae-derived antigens in a singleplex and in a multiplex assay, respectively. For the multiplex assay, the comparison between magnetic and non-magnetic beads showed: i) in the majority of the cases (13 of the 17 tested S. pneumoniae antigens) significantly higher Median Fluorescence Intensity (MFI) values, ii) lower detection limits, iii) lower coefficient of variation (CV: 12% vs. 7% for non-magnetic vs. magnetic beads), so lower inter-assay variation and hence higher reproducibility. Magnetic bead coupling is cost effective, as we used 25% of the normal amount of antigen and only 50% of the beads in comparison to the non-magnetic beads. This optimized magnetic-based assay, which combines ease of use with an improved assay performance, allows detection of antibodies with a low titer that are potentially missed with the non-magnetic-based assay.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jim.2016.06.003 | DOI Listing |
Micromachines (Basel)
December 2023
School of Chemical Engineering, Kunming University of Science and Technology, Kunming 650500, China.
Precisely controlling magnetically tagged cells in a complex environment is crucial to constructing a magneto-microfluidic platform. We propose a two-dimensional model for capturing magnetic beads from non-magnetic fluids under a micromagnetic matrix. A qualitative description of the relationship between the capture trajectory and the micromagnetic matrix with an alternating polarity configuration was obtained by computing the force curve of the magnetic particles.
View Article and Find Full Text PDFSe Pu
June 2023
Institute of Grain and Oil Quality Safety, Academy of National Food and Strategic Reserves Administration, Beijing 102629, China.
Anal Methods
October 2021
Friedrich Schiller University Jena, Institute of Physical Chemistry and Abbe Center of Photonics, Helmholtzweg 4, 07743 Jena, Germany.
Within this contribution we introduce a 3D-printed cartridge system enabling the convenient and cost-efficient sample preparation from sputum for subsequent PCR based detection schemes. The developed fluidic system operates on pneumatic actuations. The closed system ensures a very low probability for contamination during sample processing, which is crucial when using a highly sensitive detection method such as PCR.
View Article and Find Full Text PDFAn erratum was issued for: Isolation of Mouse Megakaryocyte Progenitors. A figure was updated. Figure 2 was updated from: Figure 2: Magnetic depletion of lineage committed (Lin) cells.
View Article and Find Full Text PDFMicromachines (Basel)
June 2021
Department of Mechanical Engineering, Universitat Rovira i Virgili, 43007 Tarragona, Spain.
This study analyzes experimentally the deposition of magnetic beads on the walls of a square microchannel by the action of a nearby cubical magnet. The deposition has been studied for different magnetic bead sizes, flow rates, magnetic conditions and with solutions of magnetic and non-magnetic particles. Images of the time evolution of the deposition under the different conditions have been analyzed to determine the spatial distribution of the accumulation and the growth rate of the depositions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!