Comparing the Knotless Tension Band and the Traditional Stainless Steel Wire Tension Band Fixation for Medial Malleolus Fractures: A Retrospective Clinical Study.

Scientifica (Cairo)

Foot & Ankle Division, Department of Orthopaedic Surgery, John Peter Smith Hospital, Fort Worth, TX 76104, USA; Department of Orthopaedic Surgery, Bone & Joint Institute, University of North Texas Health Science Center, Fort Worth, TX 76104, USA.

Published: June 2016

The traditional stainless steel wire tension band (WTB) has been popularized for small avulsion fractures at the medial malleolus. Despite the tension band principle creating a stable construct, complications continue to arise utilizing the traditional stainless steel WTB with patients experiencing hardware irritation at the tension band site and subsequent hardware removal. Coupled with hardware irritation is fatigue failure with the wire. The goal of this investigation was to retrospectively compare this traditional wire technique to an innovative knotless tension band (KTB) technique in order to decrease costly complications. A total of 107 patients were reviewed with a minimum follow-up of 1 year. Outcome measures include descriptive data, fracture classification, results through economic costs, and fixation results (including hardware status, healing status, pain status, and time to healing). The KTB group had a 13% lower true cost as compared to the WTB group while the fixation results were equivocal for the measured outcomes. Our results demonstrate that the innovative KTB is comparable to the traditional WTB while offering a lower true cost, an irritation free reduction all without the frustration of returning to the operating room for additional hardware removal, which averages approximately to $8,288.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4880701PMC
http://dx.doi.org/10.1155/2016/3201678DOI Listing

Publication Analysis

Top Keywords

tension band
24
traditional stainless
12
stainless steel
12
knotless tension
8
steel wire
8
wire tension
8
medial malleolus
8
hardware irritation
8
hardware removal
8
lower true
8

Similar Publications

Discovery of Titin and Its Role in Heart Function and Disease.

Circ Res

January 2025

Department of Integrative Pathophysiology, Medical Faculty Mannheim, DZHK Partnersite Mannheim-Heidelberg, University of Heidelberg, Germany (S.L.).

This review examines the giant elastic protein titin and its critical roles in heart function, both in health and disease, as discovered since its identification nearly 50 years ago. Encoded by the TTN (titin gene), titin has emerged as a major disease locus for cardiac disorders. Functionally, titin acts as a third myofilament type, connecting sarcomeric Z-disks and M-bands, and regulating myocardial passive stiffness and stretch sensing.

View Article and Find Full Text PDF

Background: Patellar fractures present challenges in treatment, with traditional methods often leading to complications such as loss of reduction and implant failure. This study aimed to compare a novel suture fixation technique with the traditional tension band method using finite element analysis.

Methods: CT images of a healthy 35-year-old male were used to construct 3D patellar models.

View Article and Find Full Text PDF

We studied the correlation between changes in the interscrew angle (screw divergence) and the correction achieved with tension band plates applied for valgus deformities of the knee region. Twenty-eight children with 68 operated physes were included in this retrospective review. The interscrew angle and screw trajectory angle were measured in the initial and follow-up radiographs.

View Article and Find Full Text PDF

This article aims to present a comprehensive technical note detailing our preferred treatment approach for tibial tuberosity avulsion fractures in the adult and elderly populations, particularly in scenarios characterized by low tissue quality and limited bone stock. Existing literature on this fracture type is scarce, with many described techniques relying on optimal bone quality for effective screw fixation of the tibial tuberosity. Various methods for tibial tuberosity avulsion fixation include K-wires, cannulated screws, staples, tension bands, suture anchors, and in select cases, direct transosseous sutures.

View Article and Find Full Text PDF

Case: A 67-year-old woman sustained a periprosthetic tibial tubercle avulsion fracture with extensor mechanism disruption. She underwent open reduction internal fixation (ORIF) with orthogonal mini-fragment plates applied in a tension band fashion with patellar tendon suture augmentation. Radiographs, range of motion, and patient-reported outcomes were completed over 1 year.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!