Background: Unstable fractures of the metacarpal and phalangeal bones of the hand need surgical stabilization which should be rigid enough for early active mobilization. Conventional methods of open reduction and stabilization in the form of composite fixation or screws with or without plates have served the purpose but can be definitely improvised addressing both biological and mechanical principles of fixation.

Materials And Methods: 34 patients (29 males and 5 females) with an average age of 32 years (range 10-64 years) with unstable fractures of the metacarpal and phalangeal bones of hand who were treated with the modified bone tie between June 2009 and June 2013 were included in this study. 42 fractures, involving the 31 metacarpals and 11 phalanges were included. We have not used this technique in fractures involving the terminal phalanges. Thirty nine of the fractures were treated with K-wires along with the modified bone tie, whereas the other two cases were treated with modified bone tie alone and in one case the bone tie has been used along with the external fixator. The nature of injuries were Road Traffic Accident (n = 24), domestic/industrial injuries (n = 8) and blast (n = 2) injuries. Etiology was crush (n = 24), blunt (n = 7) and incised (n = 3) injuries, respectively. Twenty seven patients were involved with single fractures (either metacarpal or the phalanges), 6 patients had two fractures (both metacarpals or phalanges or one each of metacarpal and phalanx), and 1 patient had three fractures in this study. Dominant hand was involved in 14 patients (40%).

Results: We achieved excellent to good results in 83% of 42 fractures within an average period of 10 weeks. Postoperative grip strength of 85% was achieved with in an average period of 12 weeks. Twenty six (20 metacarpals and 6 phalanges) of the 42 fractures regained >85% of the total active movements (TAMs) compared to the contralateral side were considered excellent results. All patients were followed up for a minimum of 1 year.

Conclusion: This method of composite fixation allowed the surgeon to remove the concomitantly used axial K-wire at or <3 weeks clearly explaining the biomechanical basis for better results with minimum complication rates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4885302PMC
http://dx.doi.org/10.4103/0019-5413.181796DOI Listing

Publication Analysis

Top Keywords

bone tie
20
fractures metacarpal
16
unstable fractures
12
metacarpal phalangeal
12
phalangeal bones
12
modified bone
12
metacarpals phalanges
12
fractures
11
bones hand
8
composite fixation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!