Background: New and expensive technology such as three-dimensional computer assisted surgery is being used for pedicle screw fixation in dorsolumbar spine. Their availability, expenses and amount of radiation exposure are issues in a developing country. On the contrary, freehand technique of pedicle screw placement utilizes anatomic landmarks and tactile palpation without fluoroscopy or navigation to place pedicle screws. The purpose of this study was to analyze and compare the accuracy of freehand and image-assisted technique to place pedicle screws in the dorsolumbar spine of cadavers by an experienced surgeon and a resident. Evaluation was done using dissection of pedicle and computed tomography (CT) imaging.

Materials And Methods: Ten cadaveric dorsolumbar spines were exposed by a posterior approach. Titanium pedicle screws were inserted from D5 to L5 vertebrae by freehand and image-assisted technique on either side by an experienced surgeon and a resident. CT was obtained. A blinded radiologist reviewed the imaging. The spines were then dissected to do a macroscopic examination. Screws, having evidence of cortical perforation of more than 2 mm on CT, were considered to be a significant breach.

Results: A total of 260 pedicle screws were placed. The surgeon and the resident placed 130 screws each. Out of 130 screws, both of them placed 65 screws each by freehand and image- assisted technique each. The resident had a rate of 7.69% significant medial and 10.76% significant lateral breach with freehand technique while with image-assisted had a rate of 3.07% significant medial and 9.23% significant lateral breach. The expert surgeon had a rate of 6.15% significant medial and 1.53% significant lateral breach with freehand technique while with image-assisted had a rate of 3.07% significant medial and 6.15% significant lateral breach on CT evaluation.

Conclusion: Freehand technique is as good as the image-assisted technique. Under appropriate supervision, residents can safely learn to place freehand pedicle screws with an acceptable violation rate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4885291PMC
http://dx.doi.org/10.4103/0019-5413.181779DOI Listing

Publication Analysis

Top Keywords

pedicle screws
20
image-assisted technique
16
freehand technique
16
lateral breach
16
pedicle screw
12
dorsolumbar spine
12
surgeon resident
12
pedicle
9
freehand
9
technique
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!