A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a sandwich enzyme-linked immunosorbent assay for the detection of CD44v3 using exon v3- and v6-specific monoclonal antibody pairs. | LitMetric

Development of a sandwich enzyme-linked immunosorbent assay for the detection of CD44v3 using exon v3- and v6-specific monoclonal antibody pairs.

J Immunol Methods

Laboratory of Molecular Cancer Therapeutics, Scripps Korea Antibody Institute, Hyoja-2-dong, Chuncheon-si, Gangwon-do 200-701, South Korea. Electronic address:

Published: September 2016

It has been suggested that soluble CD44 levels in cancer patient sera may be closely associated with tumor progression and metastasis. However, to date, there has been limited methodology for detecting the soluble CD44 variant 3 isoform (CD44v3). Herein, using phage display technology, we isolated monoclonal antibodies specific to exon v3 or v6 of CD44 (CD44-exonv3 or CD44-exonv6) from a human synthetic antibody library. We also confirmed the specificity of antibody binding to CD44-exonv3 or -exonv6. Label-free kinetic analysis using the Octet biolayer interferometry system showed that the Kd values of the anti-CD44-exonv3 and anti-CD44-exonv6 antibodies for CD44v3-10 are approximately 1.1nM and 1.5nM, respectively. Finally, we developed a sandwich enzyme-linked immunosorbent assay (ELISA) using the anti-CD44-exonv3 and anti-CD44-exonv6 antibody pairs. The minimum detection limit of the assay was 6.2ng/ml CD44v3-10 and the linear range was up to 125ng/ml. Intra- and inter-assay coefficients of variation were 2.2% and 2.9%, respectively. The intra- and inter-assay recoveries were 99.3% and 105.3%, respectively. Taken together, these results suggest that this novel sandwich ELISA using the anti-CD44-exonv3 and anti-CD44-exonv6 antibody pairs will be useful for the detection of soluble CD44v3 in cancer patient sera.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jim.2016.06.001DOI Listing

Publication Analysis

Top Keywords

antibody pairs
12
anti-cd44-exonv3 anti-cd44-exonv6
12
sandwich enzyme-linked
8
enzyme-linked immunosorbent
8
immunosorbent assay
8
soluble cd44
8
cancer patient
8
patient sera
8
elisa anti-cd44-exonv3
8
anti-cd44-exonv6 antibody
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!