Hip socket wear due to component mismatch. A case report.

Acta Orthop Scand

Department of Orthopedics, University Hospital, Lund, Sweden.

Published: April 1989

A total hip replacement with loosening of the femoral component was revised. The original femoral component with a 35-mm head was exchanged for one with a 32-mm head. The mismatch caused extensive wear of the acetabular component. The importance of preoperative planning in revision surgery is stressed.

Download full-text PDF

Source
http://dx.doi.org/10.3109/17453678909149261DOI Listing

Publication Analysis

Top Keywords

femoral component
8
hip socket
4
socket wear
4
component
4
wear component
4
component mismatch
4
mismatch case
4
case report
4
report total
4
total hip
4

Similar Publications

Purpose: Robotic-assisted total knee arthroplasty (RA-TKA) has gained popularity for its potential ability to improve surgical precision and patient outcomes, despite concerns about its long learning curve and increased operative times. The aim of this study is to evaluate the learning curve of the ROSA® Knee System, the relationship between each phase of the learning curve and the accuracy of the robotic system in femoral component size and knee alignment prediction.

Methods: A single surgeon retrospective analysis of total operative time (TOT) and total robotic time was conducted.

View Article and Find Full Text PDF

This study introduces a novel anchor-type proximal femoral nail (AT-PFN) to improve the bone-fixation integrity over the standard screw-type nail (SST-PFN). Quasi-static incremental cyclic load test was performed to investigate load-displacement, cumulative deformation energy, time-strain, and backbone curves. The finite element analysis (FEA) was implemented to identify the stress and strain distributions.

View Article and Find Full Text PDF

[Treatment with TOPS for short femoral stump].

Oper Orthop Traumatol

January 2025

Klinik für Unfall‑, Hand und Wiederherstellungschirurgie, Universitätsmedizin Rostock, Schillingallee 35, 18057, Rostock, Deutschland.

Objective: Treatment with transcutaneous osseointegrated prosthesis systems (TOPS) for short femoral amputation stumps aims to restore independent walking ability after proximal femoral amputation by direct bone-guided prosthesis anchorage. This cannot be safely achieved with conventional socket prostheses due to the mechanically inadequate socket contact surface.

Indications: Treatment of patients with short transfemoral stumps who cannot be mobilized sufficiently with conventional socket prostheses.

View Article and Find Full Text PDF

Dislocation is the second most common indication for revision total hip arthroplasty (THA). In revision cases the dislocation rate can be as high as 5-30%. The aim of this study was to assess the outcome, specifically the dislocation rate in revision THA where a dual mobility cup was used.

View Article and Find Full Text PDF

Purpose: To clarify the influence of biomechanics on post-operative clinical outcomes in bicruciate-retaining total knee arthroplasty (BCR-TKA).

Methods: Severe medial osteoarthritis who underwent BCR-TKA were examined. Each patient was asked to perform a squat (weight-bearing [WB]) and active assisted knee flexion (non-WB [NWB]) under single fluoroscopy surveillance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!