A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of sulfathiazole degradation by persulfate in Milli-Q water and in effluent of a sewage treatment plant. | LitMetric

Evaluation of sulfathiazole degradation by persulfate in Milli-Q water and in effluent of a sewage treatment plant.

Environ Sci Pollut Res Int

Chemical Engineering Department, University of São Paulo, Av. Luciano Gualberto, travessa 3, 380, São Paulo, 05508-900, Brazil.

Published: March 2017

The presence of antibiotics and their metabolites in natural waters has raised some concern among scientists around the world because it can lead to bacterial resistance and other unknown consequences to mankind and wildlife. Persulfate (PS)-driven oxidation is a new technology that has been used successfully to remediate contaminated sites, but its use to treat wastewater, especially sewage treatment plant (STP) effluent, is still scarce. This paper describes the effect of several persulfate activation methods for degrading sulfathiazole (STZ) in Milli-Q water and in STP effluent. Some parameters, such as pH, persulfate concentration, presence of Mn, Zn, Cu, Fe, and Fe, as well as copper and iron organic complexes, were studied in STZ degradation. Raising the pH from 5 to 9, as well as the persulfate concentration, resulted in increased STZ degradation. Among the transition metals evaluated, only Fe and Cu were able to activate persulfate molecules. Copper was a better activator than iron since its effect lasts longer. Citrate was the best ligand evaluated increasing Fe(II) activation capacity at pH 7. Hydroxylamine addition to Fe(II) on persulfate system extended the Fe(II) effect. The presence of bicarbonate or humic acid did not affect PS-driven degradation of STZ. Finally, the degradation of STZ in STP effluent promoted by PS-driven oxidation (25 °C) was as fast as in Milli-Q water, proving to be successful.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11356-016-7036-zDOI Listing

Publication Analysis

Top Keywords

milli-q water
12
stp effluent
12
sewage treatment
8
treatment plant
8
ps-driven oxidation
8
persulfate concentration
8
stz degradation
8
degradation stz
8
persulfate
7
degradation
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!