Background: The correlation between impedance cardiography (ICG) and 6 min walk distance (6MWD) in atrial fibrillation (AF) patients remains unknown.

Methods: We recruited 49 subjects in the study (21 AF patients and 28 patients without AF) and estimated hemodynamic parameters: cardiac output (CO), stroke volume (SV), stroke volume index (SVI), left stroke work (LSW), left stroke work index (LSWI), stroke systemic vascular resistance (SSVR), stroke systemic vascular resistance index (SSVRI); 6MWD, left ventricle ejection fraction (LVEF), NT-pro brain natriuretic peptide (NT-pro BNP) for the two groups.

Results: The AF group have apparently lower CO (2.26 ± 0.14 VS 4.11 ± 0.20 L/min, p = 0.039) and distinctly higher SVR (677.60 ± 69.10 VS 344.41 ± 22.98 dynes/cm(5), p = 0.001), SSVRI (396.97 ± 36.80 VS 199.01 ± 11.72 dynes/cm(5)/m(2), p < 0.001) than the control group. NT-pro BNP (1409.48 ± 239.90 VS 332.59 ± 68.85 pg/ml, p = 0.001) in the AF group was significantly higher than the control group and 6MWD (264.33 ± 14.55 VS 428.79 ± 29.98 m, p < 0.001) in the AF group was lower than the control group. There was no significant difference in LVEF between the two groups (62.67 ± 7.62 % VS 63.93 ± 5.03 %, p = 0.470). Pearson correlation analysis revealed that CO (R = 0.494, p = 0.023), SV (R = 0.633, p = 0.002), LSW (R = 0.615, p = 0.003) and LSWI (R = 0.491, p = 0.024) significantly correlated positively with 6MWD in AF patients.

Conclusions: AF patients had lower cardiac output, shorter 6MWD and higher NT-pro BNP than patients with sinus rhythm. The cardiac output measured by impedance cardiography significantly correlated positively with 6MWD in AF patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4901461PMC
http://dx.doi.org/10.1186/s12872-016-0297-0DOI Listing

Publication Analysis

Top Keywords

correlation impedance
8
impedance cardiography
8
6 min walk
8
walk distance
8
atrial fibrillation
8
fibrillation patients
8
stroke volume
8
left stroke
8
stroke work
8
stroke systemic
8

Similar Publications

Background: Accurate assessment of fluid volume and hydration status is essential in many disease states, including patients with chronic kidney disease. The aim of this study was to investigate the ability of a wearable continuous bioimpedance sensor to detect changes in fluid volume in patients undergoing regular hemodialysis (HD).

Methods: 31 patients with end-stage renal disease were enrolled and monitored with a sensor patch (Re:Balans) on the upper back through two consecutive HD sessions and the interdialytic period between.

View Article and Find Full Text PDF

Background/aims: Distal mean nocturnal baseline impedance (MNBI) measuring via pH-impedance may be valuable in diagnosing patients with suspected laryngopharyngeal reflux (LPR). However, its wide adoption is hindered by cost and invasiveness. This study investigates whether baseline impedance measured during high-resolution impedance manometry (HRIM-BI) can predict pathological MNBI.

View Article and Find Full Text PDF

The pH of venison is affected by deer capture methods, which affects its water-holding capacity (WHC) during heating. Therefore, cooking or processing venison requires careful consideration of WHC at different pH levels. While this requires nondestructively measuring the pH of venison during distribution, there are no established methods to nondestructively distinguish between normal- and high-pH meats.

View Article and Find Full Text PDF

This study aimed to evaluate the body composition of the Khisêdjê, an Indigenous people residing in the Xingu Indigenous Territory, and compare it to the results obtained by anthropometry. One hundred seventy-nine individuals aged above 20 of both genders were included. The nutritional status was classified per the cutoff proposed by the WHO (1995).

View Article and Find Full Text PDF

Background/objective: Obesity is linked to increased risks of cardiovascular disease, diabetes, and certain cancers. Bariatric surgery (BS) aids in weight management, significantly altering body composition. This study evaluates the predictive value of five complete blood count (CBC)-derived indices [C-reactive-protein-albumin-lymphocyte (CALLY), glucose-to-lymphocyte ratio (GLR), prognostic nutritional index (PNI), hemoglobin, albumin, lymphocyte, platelet (HALP), and controlling nutritional status (COUNT)] on body composition changes post-BS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!