We evaluated the performance of the VIDAS GDH assay for the detection of Clostridium difficile. In total, 350 fecal specimens collected from patients clinically suspected of having CDI were analyzed by C. difficile culture and enzyme-linked fluorescent immunoassay (VIDAS GDH); the results were compared with those of toxigenic C. difficile culture (TC), PCR (Xpert C. difficile assay), and toxin AB EIA (VIDAS CDAB). The numbers of culture-positive and culture-negative samples were 108 and 242, respectively. The concordance between the GDH assay and C. difficile culture was 90.3%. With PCR, 12 more samples were found to be positive in GDH-positive/C. difficile culture-negative specimens. Thus, the concordance between GDH assay and C. difficile culture/PCR was 93.7%. The sensitivity, specificity, positive predictive value, and negative predictive value of the VIDAS GDH assay were 97.2%, 87.2%, 77.2%, and 98.6%, respectively, based on the C. difficile culture, and 97.5%, 91.7%, 86.0%, and 98.6%, respectively, based on C. difficile culture/PCR. Positivity rates of the GDH assay were partially associated with those of semi-quantitative C. difficile cultures, which were maximized in grade 3 (>100 colony-forming unit [CFU]) compared with grade 1 (<10 CFU). We evaluated the two-step or three-step algorithm using GDH assay as a first step. No toxin EIA-positive case was found among GDH-negative samples, and 60.8% (48/79) were TC- and/or PCR-positive among the GDH-positive/toxin EIA-negative samples. Thus, approximately 25% of the 350 samples required a confirmatory test (TC or PCR) in the GDH-toxin EIA algorithm, whereas only 2.3% of the total samples in GDH-PCR algorithm was discrepant and required another confirmatory test like TC.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.anaerobe.2016.06.001DOI Listing

Publication Analysis

Top Keywords

gdh assay
20
c difficile culture
16
vidas gdh
12
assay detection
8
detection clostridium
8
clostridium difficile
8
c difficile
8
concordance gdh
8
assay c difficile
8
c difficile culture/pcr
8

Similar Publications

[Evaluation of Quick Chaser CD GDH/TOX, a Rapid Diagnostic Kit for Simultaneous Detection of Antigen and Toxin A/B, in Fecal Specimens].

Rinsho Biseibutshu Jinsoku Shindan Kenkyukai Shi

December 2024

Department of Clinical Laboratory, Medical Kouhoukai Takagi Hospital. Department of Medical Laboratory Science, Graduate school of Health and Welfare Sciences, International University of Health and Welfare Graduate School.

For infections, highly sensitive rapid diagnostic test kits are necessary for prompt diagnose and infection control. In this study, we evaluated "Quick Chaser CD GDH/TOX" (evaluation kit), a rapid diagnostic kit for , using 65 clinical stool specimens, comparing with GE test immunochromato-CD GDH/TOX "Nissui" (GE test) and TECHLAB QUIK CHEK COMPLETE (QUIK CHEK). The results of the evaluation kit showed a high concordance rate; 100% the positive concordance rate (31/31) and 97.

View Article and Find Full Text PDF

Perfusion Showdown: Comparison of Multiple MRI Perfusion Techniques in the Grading of Pediatric Brain Tumors.

AJNR Am J Neuroradiol

December 2024

From the Department of Diagnostic Medicine, Dell Medical School at The University of Texas at Austin, Austin, TX, USA (C.Y.H.), Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, USA (N.S., G.A., Q.W., P.C., M.A., J.G.P., B.R.G., P.R.T., G.D.H.), Department of Medicine, Indiana University School of Medicine, Indianapolis, IN, USA (E.C., P.R.T., S.A.P.), Stark Neuroscience Research Institute, Indiana University School of Medicine, Indianapolis, IN, USA (P.R.T., S.A.P.), and the Department of Radiology at Texas Children's Hospital, Houston, TX, USA (S.F.K.).

Background And Purpose: There are multiple MRI perfusion techniques, with limited available literature comparing these techniques in the grading of pediatric brain tumors. For efficiency and limiting scan time, ideally only one MRI perfusion technique can be used in initial imaging. We compared DSC, DCE, and IVIM along with ADC from DWI for differentiating high versus low grade pediatric brain tumors.

View Article and Find Full Text PDF

SIRT5-mediated GLS and GDH desuccinylation attenuates the autophagy of bovine mammary epithelial cells induced by ammonia.

Cell Signal

December 2024

Key Laboratory of Animal Biochemistry and Nutrition, Ministry of Agriculture, College of Veterinary Medicine, Henan Agricultural University, Zhengzhou 450046, Henan, China; Key Laboratory of Veterinary Biotechnology of Henan Province, College of Veterinary Medicine, Henan Agricultural University, Zhengzhou 450046, Henan, China; Ministry of Education Key Laboratory for Animal Pathogens and Biosafety, College of Veterinary Medicine, Henan Agricultural University, Zhengzhou 450046, Henan, China. Electronic address:

Sirtuin 5 (SIRT5) in mitochondria possesses a strong capacity for lysine desuccinylation, involving in various biological processes. Our previous research demonstrated that NH regulated autophagy dependent on SIRT5 in bovine mammary epithelial cells (bMECs). Interestingly, we discovered that SIRT5 reduced the content of NH and glutamate by inhibiting GLS activity in bMECs, the ratio of ADP/ATP also declined.

View Article and Find Full Text PDF

Gene Expression Dysregulation in Whole Blood of Patients with Infection.

Int J Mol Sci

November 2024

Department of Pharmacology and Therapeutics, Institute of Systems Molecular and Integrative Biology, University of Liverpool, Liverpool L69 3GL, UK.

() is a global threat and has significant implications for individuals and health care systems. Little is known about host molecular mechanisms and transcriptional changes in peripheral immune cells. This is the first gene expression study in whole blood from patients with infection.

View Article and Find Full Text PDF

Background: Growth hormone (GH) treatment is effective in restoring normal growth in children with GH deficiency (GHD). However, individual responses to GH treatment vary, necessitating predictive models to estimate growth outcomes. This study aimed to develop and validate a predictive model for GH treatment response during the first 2 years in patients with idiopathic GHD using the LG growth study (LGS) database.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!