Purpose: To determine graft bending angle (GBA) during knee motion after anatomic anterior cruciate ligament (ACL) reconstruction and to clarify whether surgical techniques affect GBA. Our hypotheses were that the graft bending angle would be highest at knee extension and the difference of surgical techniques would affect the bending steepness.

Methods: Eight healthy volunteers with a mean age of 29.3 ± 3.0 years were recruited and 3D MRI knee models were created at three flexion angles (0°, 90° and 130°). Surgical simulation of the tunnel drilling was performed with anatomic tunnel position using each outside-in (OI), trans-portal (TP) and trans-tibial (TT) techniques on the identical cases. The models were matched to other knee positions and the GBA in 3D was measured using computational software. Double-bundle ACL reconstruction was analysed first, and single-bundle reconstruction was also analysed to evaluate its effect to reduce GBA. A repeated-measures ANOVA was used to compare GBA difference at three flexion angles, by three techniques or of three bundles.

Results: GBA changed substantially with knee motion, and it was highest at full extension (p < 0.001) in each surgical technique. OI technique exhibited highest GBA for anteromedial bundle (94.3° ± 5.2°) at extension, followed by TP (83.1° ± 6.5°) and TT (70.0° ± 5.2°) techniques (p < 0.01). GBA for posterolateral bundle at extension were also high in OI (84.6° ± 7.4°), TP (83.0° ± 6.3°) and TT (77.2° ± 7.0°) techniques (n.s.). Single-bundle grafts did not decrease GBA compared with double-bundle grafts. In OI technique, a more proximal location of the femoral exit reduced GBA of each bundle at extension and 90° flexion.

Conclusion: A significant GBA change with knee motion and considerably steep bending at full extension, especially with OI and TP techniques, were simulated. Although single-bundle technique did not reduce GBA as seen in double-bundle technique, proximal location of femoral exits by OI technique, with tunnels kept in anatomic position, was effective in decreasing GBA at knee extension and flexion. For clinical relevance, high stress on graft and bone interface has been suggested by steep GBA at full extension after anatomic ACL reconstruction.

Level Of Evidence: Therapeutic study (prospective comparative study), Level II.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-016-4191-1DOI Listing

Publication Analysis

Top Keywords

graft bending
12
bending angle
12
knee motion
12
outside-in trans-portal
8
trans-portal trans-tibial
8
anterior cruciate
8
cruciate ligament
8
acl reconstruction
8
surgical techniques
8
techniques affect
8

Similar Publications

Facial Fat Grafting Cannula: A Tool to Facilitate Closed Irrigation in Flexor Tenosynovitis.

Plast Reconstr Surg Glob Open

January 2025

From the Division of Plastic and Reconstructive Surgery, Mayo Clinic, Rochester, MN.

Pyogenic flexor tenosynovitis (PFT), also known as septic or suppurative flexor tenosynovitis, is a closed-space infection of the hand's flexor tendon sheath that necessitates timely diagnosis and treatment. The treatment consists of antibiotic therapy often combined with prompt surgical treatment. The most common surgical approach is the closed irrigation technique, which involves inserting a 16-gauge angiocatheter in the proximal aspect of the flexor tendon sheath, leaving the distal end of the Brunner incision open during the irrigation process.

View Article and Find Full Text PDF

The freely jointed chain model with reversible hinges (rFJC) is the simplest theoretical model, which captures reversible transitions of the local bending stiffness along the polymer chain backbone (e.g., helix-coil-type of local conformational changes or changes due to the binding/unbinding of ligands).

View Article and Find Full Text PDF

Background: Biliary stricture is a common complication after living-donor liver transplantation (LDLT), but its management is challenging. We herein report a case of successful internal drainage achieved through combination of the gun-sight technique and dual hepatic vascular embolization (DHVE).

Case Presentation: A 54-year-old woman with primary biliary cholangitis underwent ABO-incompatible LDLT with the right lobe.

View Article and Find Full Text PDF

Peripheral nerve injuries (PNI) represent the most common type of nervous system injuries, resulting in 5 million injuries per year. Current gold standard, autografts, still carry several limitations, including the inappropriate type, size, and function matches in grafted nerves, lack of autologous donor sites, neuroma formation, and secondary surgery incisions. Polymeric nerve conduits, also known as nerve guides, can help overcome the aforementioned issues that limit nerve recovery and regeneration by reducing tissue fibrosis, misdirection of regenerating axons, and the inability to maintain long- distance axonal growth.

View Article and Find Full Text PDF
Article Synopsis
  • * It is created by polymerizing AMB monomer with gelatin, crosslinking it, and embedding strontium titanate nanoparticles, resulting in a hydrogel with strong tissue adhesion and the ability to generate voltage and current through mechanical motion.
  • * In trials with mice, the SPG hydrogel significantly expedited the healing process, reducing wound size and improving skin quality, indicating its potential as an innovative tool for electrotherapy in wound care.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!