The head and neck region is one of the most complex areas featured in the medical gross anatomy curriculum. The effectiveness of using three-dimensional (3D) models to teach anatomy is a topic of much discussion in medical education research. However, the use of 3D stereoscopic models of the head and neck circulation in anatomy education has not been previously studied in detail. This study investigated whether 3D stereoscopic models created from computed tomographic angiography (CTA) data were efficacious teaching tools for the head and neck vascular anatomy. The test subjects were first year medical students at the University of Mississippi Medical Center. The assessment tools included: anatomy knowledge tests (prelearning session knowledge test and postlearning session knowledge test), mental rotation tests (spatial ability; presession MRT and postsession MRT), and a satisfaction survey. Results were analyzed using a Wilcoxon rank-sum test and linear regression analysis. A total of 39 first year medical students participated in the study. The results indicated that all students who were exposed to the stereoscopic 3D vascular models in 3D learning sessions increased their ability to correctly identify the head and neck vascular anatomy. Most importantly, for students with low-spatial ability, 3D learning sessions improved postsession knowledge scores to a level comparable to that demonstrated by students with high-spatial ability indicating that the use of 3D stereoscopic models may be particularly valuable to these students with low-spatial ability. Anat Sci Educ 10: 34-45. © 2016 American Association of Anatomists.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ase.1626 | DOI Listing |
Bioact Mater
April 2025
Department of Orthopaedics, Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, PR China.
Bioelectrical stimulation is a powerful technique used to promote tissue regeneration, but it can be hindered by an "electrical overload" phenomenon in the core region of stimulation. We develop a threaded microneedle electrode system that protects against "electrical overload" by delivering medicinal hydrogel microspheres into the core regions. The threaded needle body is coated with polydopamine and chitosan to enhance the adhesion of microspheres, which are loaded into the threaded grooves, allowing for their stereoscopic release in the core regions.
View Article and Find Full Text PDFBrain Sci
November 2024
School of Optometry and Vision Sciences, Bar-Ilan University, Ramat Gan 5290002, Israel.
Binocular vision may serve as a good model for research on awareness. Binocular summation (BS) can be defined as the superiority of binocular over monocular visual performance. Early studies of BS found an improvement of a factor of about 1.
View Article and Find Full Text PDFSci Rep
December 2024
College of Safety Science and Engineering, Liaoning Technical University, 47 Zhonghua Road, Xihe District, Fuxin City, 123000, Liaoning Province, China.
Based on the engineering example of Linsheng coal mine, this paper uses TF1M3D computer simulation platform to systematically analyze the process of smoke flow spreading and air flow disorder disaster from the perspective of the whole mine network, and puts forward corresponding plans and measures. A small scale similar experiment was carried out to study the updraft flow fire in the mine. Through the analysis of the collected experimental data, the variation law of the air volume of the fire source in the main air path, side branch road and total air path with different air volume and the variation characteristics of the temperature at the monitoring point with time were obtained under different air volume conditions, and the critical air volume was fitted as 1.
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
December 2024
Department of Cardiothoracic Surgery, Erasmus University Medical Center, Rotterdam, The Netherlands.
Purpose: In this feasibility study, we aimed to create a dedicated pulmonary augmented reality (AR) workflow to enable a semi-automated intraoperative overlay of the pulmonary anatomy during video-assisted thoracoscopic surgery (VATS) or robot-assisted thoracoscopic surgery (RATS).
Methods: Initially, the stereoscopic cameras were calibrated to obtain the intrinsic camera parameters. Intraoperatively, stereoscopic images were recorded and a 3D point cloud was generated from these images.
NPJ Digit Med
December 2024
Department of Ophthalmology and Visual Sciences, University of Iowa, Iowa City, IA, USA.
Where adopted, Autonomous artificial Intelligence (AI) for Diabetic Retinal Disease (DRD) resolves longstanding racial, ethnic, and socioeconomic disparities, but AI adoption bias persists. This preregistered trial determined sensitivity and specificity of a previously FDA authorized AI, improved to compensate for lower contrast and smaller imaged area of a widely adopted, lower cost, handheld fundus camera (RetinaVue700, Baxter Healthcare, Deerfield, IL) to identify DRD in participants with diabetes without known DRD, in primary care. In 626 participants (1252 eyes) 50.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!