A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of a new sampling buffer on faecal haemoglobin stability in a colorectal cancer screening programme by the faecal immunochemical test. | LitMetric

Impact of a new sampling buffer on faecal haemoglobin stability in a colorectal cancer screening programme by the faecal immunochemical test.

Eur J Cancer Prev

aScreening Unit bClinical and Descriptive Epidemiology Unit cLaboratory Unit, Cancer Prevention and Research Institute (ISPO) Florence dGeneral Laboratory, Laboratory Department, Careggi Hospital, Florence, Italy.

Published: July 2017

Haemoglobin (Hb) stability in faecal samples is an important issue in colorectal cancer screening by the faecal immunochemical test (FIT) for Hb. This study evaluated the performance of the FIT-Hb (OC-Sensor Eiken) used in the Florence screening programme by comparing two different formulations of the buffer, both in an analytical and in a clinical setting. In the laboratory simulation, six faecal pools (three in each buffer type) were stored at different temperatures and analysed eight times in 10 replicates over 21 days. In the clinical setting, 7695 screenees returned two samples, using both the old and the new specimen collection device (SCD). In the laboratory simulation, 5 days from sample preparation with the buffer of the old SCD, the Hb concentration decreased by 40% at room temperature (25°C, range 22-28°C) and up to 60% at outside temperature (29°C, range 16-39°C), whereas with the new one, Hb concentration decreased by 10%. In the clinical setting, a higher mean Hb concentration with the new SCD compared with the old one was found (6.3 vs. 5.0 µg Hb/g faeces, respectively, P<0.001); no statistically significant difference was found in the probability of having a positive result in the two SCDs. Better Hb stability was observed with the new buffer under laboratory conditions, but no difference was found in the clinical performance. In our study, only marginal advantages arise from the new buffer. Improvements in sample stability represent a significant target in the screening setting.

Download full-text PDF

Source
http://dx.doi.org/10.1097/CEJ.0000000000000257DOI Listing

Publication Analysis

Top Keywords

clinical setting
12
haemoglobin stability
8
colorectal cancer
8
cancer screening
8
screening programme
8
faecal immunochemical
8
immunochemical test
8
laboratory simulation
8
concentration decreased
8
faecal
5