The paper presents a study of the sorption properties of sediments of different geological ages and lithological types, governing radionuclide retention in the subsurface (up to 160 m beneath the surface) within the area of potential influence of the Northwestern Center of Atomic Energy (NWCAE), St. Petersburg region, RF. The focus of this work is mostly on the sedimentary rocks of two types, i.e., weakly cemented sandstone and lithified clay formations of Cambrian and Vendian series. The first lithological unit is associated with a groundwater reservoir (Lomonosov aquifer), and the second one, with both a relative aquitard in the upper part of the Vendian formation (Kotlin clay) and a regional aquifer (Gdov aquifer) in the lower part of the formation. The main mechanisms responsible for the variability of the sorption distribution coefficient (Kd, defined as the ratio of the concentration of solute on solid phase to its concentration in solution at equilibrium) was identified for radionuclides such as Sr-90, Cs-137, Co-60, Pu-239,240, and Am-241. It was shown that the main factors contributing to the chemical heterogeneity of the Cambrian sandstone were related to the presence of secondary minerals (iron and magnesium oxides and hydroxides produced by the weathering process) in trace amounts, forming correlated layer structures. The statistical analysis of nonlinear isotherms confirmed this conclusion. For the Vendian formation, a determinate trend was established in the Kd change over depth as a result of temporal trends in the sedimentation process and pore-water chemistry. The geostatistical characteristics and the spatial correlation models for describing linear sorption of different radionuclides are not identical, and the exhibition of chemical heterogeneity of sedimentary rock of a particular lithological type depends on radionuclide chemistry. Moreover, variogram analysis for some Kd data sets (both in Cambrian and Vendian formations) demonstrates the total absence of auto-correlation (pure nugget effect). It can be supposed that sampling distances did not allow the evaluation of small-scale variability in sediment sorption properties.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jenvrad.2016.05.030DOI Listing

Publication Analysis

Top Keywords

radionuclides sr-90
8
sr-90 cs-137
8
cs-137 co-60
8
co-60 pu-239240
8
pu-239240 am-241
8
petersburg region
8
sorption properties
8
cambrian vendian
8
vendian formation
8
chemical heterogeneity
8

Similar Publications

Surface contamination monitors are used intensively in many facilities, like in the nuclear medicine departments for clearance measurements and decontamination and in decommissioning of nuclear installations. For a reliable use, all surface contamination monitors should have a valid calibration with traceability to the international standards. A comparison exercise for calibrations in terms of efficiency in 2π steradian for surface contamination monitors was organized between five dosimetry calibration laboratories, members of EURAMET (The European Association of National Metrology Institutes).

View Article and Find Full Text PDF

Monitoring of the content of technogenic radionuclides (Cs-137 and Sr-90) in foods is one of the key areas in ensuring radiation safety of the population, taking into account the current radiation situation. The greatest risk to health is food produced or imported from the territories that have been subjected to man-made radiation accidents. of the research was to assess the radiation risk caused by oral intake of radionuclides based on the study of the actual nutrition of the adult population and contamination of food with Cs-137 and Sr-90 radionuclides.

View Article and Find Full Text PDF

Investigation of select radionuclides stability in urine under various conditions for liquid scintillation counting (LSC).

J Radioanal Nucl Chem

January 2024

Inorganic and Radiation Analytical Toxicology Branch, Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Hwy, MS S110-5, 30341-3717 Atlanta, GA, Georgia.

Liquid Scintillation Counting (LSC) gross alpha/beta screening is a valuable tool for providing rapid laboratory response for the analysis of human clinical urine samples during a large-scale radiation incident event. Verification of method performance, as required for clinical laboratory testing, is accomplished by the evaluation of routine, periodic measurements of radioactive spiked samples for quality control, performance testing, and accuracy checks. Radionuclide stability of alpha and beta emitters in urine for LSC analysis is an important consideration.

View Article and Find Full Text PDF

Processing biological samples from simulated radiological terrorist events using Rapid DNA instruments.

Forensic Sci Int

January 2024

Royal Canadian Mounted Police, Forensic Science & Identification Services, Science & Strategic Policy, 1200 Vanier Parkway, Ottawa, Ontario K1A 0R2, Canada.

Two commercially available portable Rapid DNA instruments were evaluated for their ability to process 1 µL and 10 µL saliva samples deposited on metal and plastic surfaces and contaminated with surrogates of cesium (Cs)-137, strontium (Sr)-90 and cobalt (Co)-60; radioactive materials potentially released during a nuclear weapon accident or a radiological dispersal device detonation. A comparable success rate was noted for both Rapid DNA instruments when considering the number of complete and balanced DNA profiles, the number of profiles with a minimum of 10 autosomal STR loci (out of 23 [FlexPlex™ 27] or 21 [GlobalFiler™ Express]), and the possibility to search a national DNA database in Canada and the United States. Cobalt had an adverse impact on the quality of the megaplex short tandem repeat (STR) DNA profiles derived on each instrument for two of the three contamination levels tested in this study, i.

View Article and Find Full Text PDF

Simultaneous determination of Pb and Sr and Po isolation in sludge samples using a plastic scintillation resin.

Appl Radiat Isot

February 2023

Departament de Química Analítica i Química Orgànica, Universitat Rovira i Virgili Unitat de Radioquímica Ambiental i Sanitaria, Consorci d'Aigües de Tarragona (CAT), Ctra. Nacional 340, Km. 1094, 43895, L'Ampolla, Tarragona, Spain.

This study describes a new and fast method for separating Po from Pb and Sr, before simultaneously measuring the individual activities of the latter two radionuclides using a plastic scintillation resin (PSresin) in sludge samples taken from a drinking water treatment plant. This method speeds up the analysis process significantly by simultaneously measuring Pb and Sr in a single step. The method is reproducible and has a relative standard deviation of less than 25% for Pb, Po and Sr.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!