Background And Objective: Iterative reconstruction from Compton scattered data is known to be computationally more challenging than that from conventional line-projection based emission data in that the gamma rays that undergo Compton scattering are modeled as conic projections rather than line projections. In conventional tomographic reconstruction, to parallelize the projection and backprojection operations using the graphics processing unit (GPU), approximated methods that use an unmatched pair of ray-tracing forward projector and voxel-driven backprojector have been widely used. In this work, we propose a new GPU-accelerated method for Compton camera reconstruction which is more accurate by using exactly matched pair of projector and backprojector.
Methods: To calculate conic forward projection, we first sample the cone surface into conic rays and accumulate the intersecting chord lengths of the conic rays passing through voxels using a fast ray-tracing method (RTM). For conic backprojection, to obtain the true adjoint of the conic forward projection, while retaining the computational efficiency of the GPU, we use a voxel-driven RTM which is essentially the same as the standard RTM used for the conic forward projector.
Results: Our simulation results show that, while the new method is about 3 times slower than the approximated method, it is still about 16 times faster than the CPU-based method without any loss of accuracy.
Conclusions: The net conclusion is that our proposed method is guaranteed to retain the reconstruction accuracy regardless of the number of iterations by providing a perfectly matched projector-backprojector pair, which makes iterative reconstruction methods for Compton imaging faster and more accurate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.cmpb.2016.04.012 | DOI Listing |
Acta Orthop
January 2025
Emeritus Consultant Orthopaedic Surgeon, Wrightington Hospital; Bristol University, UK.
Background And Purpose: The amount of information publicly available from arthroplasty registries is large but could be used more effectively. This project aims to improve the knowledge concerning existing registries to facilitate access, transparency, harmonization, and reporting.
Methods: Within the International Society of Arthroplasty Registries (ISAR) we aimed at developing, testing, adopting, and making publicly available a short, standardized registry description with items considered relevant for stakeholders using a cross-sectional study survey.
Neuroradiol J
January 2025
Department of Radiology and Radiological Science, Medical University of South Carolina, USA.
We describe a novel application of photon-counting detector CT (PCD-CT) in neurovascular imaging by harnessing the improved spatial resolution, attenuation of electronic noise, and reduction of metal artifacts. The presented case offers the unique challenge of high-quality imaging for the assessment of treated and untreated intracranial saccular aneurysms, in the setting of metal artifacts from embolization coils. Our goal was to explore optimized reconstruction parameters for ultra-high-resolution imaging (UHR) using a dedicated, sharp neurovascular kernel (Hv72) and the highest strength of quantum iterative reconstruction (QIR-4) for detailed characterization of the vasculature.
View Article and Find Full Text PDFJ Comput Assist Tomogr
January 2025
Department of Radiology, the Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University.
Background: With the widespread use of lumbar pedicle screws for internal fixation, the morphology of the screws and the surrounding tissues should be evaluated. The metal artifact reduction (MAR) technique can reduce the artifacts caused by pedicle screws, improve the quality of computed tomography (CT) images after pedicle fixation, and provide more imaging information to the clinic.
Purpose: To explore whether the MAR+ method, a projection-based algorithm for correcting metal artifacts through multiple iterative operations, can reduce metal artifacts and have an impact on the structure of the surrounding metal.
Synchrotron X-ray microtomography (S-µCT) is a highly valuable technique for investigating organ function and pathologies. However, its application is often limited by high radiation doses and the occurrence of ring artifacts. While S-µCT utilizing sparse-view projections can effectively decrease radiation doses, the reconstructed images frequently exhibit severe streaking artifacts, which are exacerbated by ring artifacts, ultimately compromising reconstruction accuracy, image quality, and resolution.
View Article and Find Full Text PDFDue to their advantages of compact geometries and lightweight, diffractive optical elements (DOEs) are attractive in various applications such as sensing, imaging and holographic display. When designing DOEs based on algorithms, a diffraction model is required to trace the diffracted light propagation and to predict the performance. To have more precise diffraction field tracing and optical performance simulation, different diffraction models have been proposed and developed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!