Purpose: The diagnosis of Mycobacterium avium complex pulmonary disease (MAC-PD) can be challenging. A serodiagnosis enzyme immunoassay (EIA) kit, which detects the serum anti-glycopeptidolipid (GPL) core IgA antibody, has been commercialized recently; however, its clinical usefulness in the diagnosis of MAC-PD is still unclear. This study aimed to evaluate the availability of this kit and identify factors affecting testing accuracy.

Methods: We performed a retrospective study of 195 patients who were evaluated with an EIA kit at Nagasaki University Hospital between November 2012 and March 2014.

Results: 12 of 16 (75.0%) MAC patients have underlying diseases ; 8 of 16 (50%) had complications associated with respiratory diseases. There were no significant differences between the seropositive and seronegative background of patients with confirmed MAC-PD. Regarding the accuracy of serodiagnosis EIA kit, its sensitivity and specificity were 81.3% and 88.3% (with a cut-off value of 0.7 U/ml), respectively. Of false-positive patients with bronchiectasis, 28.6 % demonstrated a good response to anti-MAC treatment, indicating that the sensitivity of the EIA kit might be higher than that of culture-based diagnosis because patients with clinically diagnosed MAC-PD were included in the false-positive population.

Conclusions: In the current study, the serodiagnosis EIA kit demonstrated good sensitivity and specificity for the diagnosis of MAC-PD. Further clinical investigations are necessary to clarify the role of this kit in definitively diagnosing MAC infections.

Download full-text PDF

Source

Publication Analysis

Top Keywords

eia kit
20
mycobacterium avium
8
avium complex
8
diagnosis mac-pd
8
serodiagnosis eia
8
sensitivity specificity
8
demonstrated good
8
kit
7
mac-pd
5
eia
5

Similar Publications

Article Synopsis
  • Histoplasmosis is particularly dangerous for HIV patients, especially where antiretroviral therapy is hard to get, making antigen detection assays vital for quick diagnoses and reducing mortality.
  • The study assessed 27 HIV patients with histoplasmosis over 24 weeks, monitoring urinary Histoplasma antigen levels as they received treatment with amphotericin B followed by itraconazole.
  • Results indicated that as antigen levels decreased, patient clinical outcomes improved, suggesting that the clarus Histoplasma GM EIA kit could effectively monitor treatment responses, despite some patients having atypical antigen patterns due to immune system responses or medication absorption issues.
View Article and Find Full Text PDF

Introduction: We evaluated the application of a newly improved enzyme immunoassay (EIA) kit, Mumps IgG Seiken®, by comparing antibody responses to different EIA kits, and neutralization tests (NTs), using clinical samples.

Methods: Serum samples were collected before and 4-6 weeks after vaccination from 128 children who had no history of mumps or mumps vaccination. Using three different EIA kits, Mumps IgG Seiken®, a commercial kit from Enzygnost®, and an in-house kit, mumps-specific IgG antibodies were measured.

View Article and Find Full Text PDF

Comparison of Cortisol Levels in the Hair of Male European Roe Deer at the Beginning and End of the Stalking Hunting Season.

Animals (Basel)

November 2024

Department of Invertebrate Ecophysiology and Experimental Biology, Faculty of Animal Sciences and Bioeconomy, University of Life Sciences in Lublin, 50A Doświadczalna Street, 20-280 Lublin, Poland.

Roe deer (), as a representative of the Cervidae family, are particularly sensitive to negative environmental stimuli due to their need to maintain increased vigilance during feeding. Intensive hunting seasons are undoubtedly also a stressful factor for this species. The aim of this study was to analyze the cortisol levels in the hair of male roe deer collected at the beginning and the end of the hunting season in eastern Poland.

View Article and Find Full Text PDF
Article Synopsis
  • Chronic antibody-mediated rejection is a significant cause of kidney transplant failure due to immune complexes formed by donor-specific antibodies (DSAs) and antigens.
  • The study aimed to assess levels of circulating C1q immunocomplexes (CIC-C1q) and overall complement activation (CH50) in sensitized kidney transplant recipients, comparing those with and without DSAs to control subjects.
  • Findings revealed higher CIC-C1q levels in transplant recipients with DSAs, along with lower CH50 levels, indicating increased complement activation linked to DSA presence, while no significant differences were observed in recipients without DSAs compared to controls.
View Article and Find Full Text PDF
Article Synopsis
  • Assessing measles risk in infants 6-12 months is crucial, but there's limited data on ELISA tests for those under 9 months.
  • A study used a commercial ELISA kit to evaluate measles immunity in infants aged 5-7 months, comparing results with the more complex PRNT method at various time points after vaccination.
  • Findings showed low correlation between ELISA and PRNT results, with ELISA often underestimating immunity, indicating a need for more accurate testing to prevent vaccine failures during outbreaks.*
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!