Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background/purpose: Among DNA-based techniques, polymerase chain reaction (PCR) is the most widely accepted molecular tool for the detection of pathogens. However, the technique involves several reagents and multiple pipetting steps that often lead to error-prone results. Additionally, the reagents entail a cold-chain facility to maintain their stability during storage and transportation. The main aim of the present study was to simplify the utility of a pre-optimized multiplex PCR format that was developed to detect toxigenic strains of Staphylococcus aureus by providing stable, pre-mixed, and ready-to-use master mix in a lyophilized formulation.
Methods: Master mix containing all reagents except the template was lyophilized in the presence of an excipient lyoprotectant to achieve long-term stability without altering the sensitivity, specificity and PCR performance. Bromophenol blue was also included in the master mix to reduce the risk of external contamination during gel loading. The stability of lyophilized master mix was analyzed at different temperatures. The PCR performance was also examined after exposure of master mix to notable temperature fluctuations during transportation.
Results: The shelf-life of lyophilized master mix was estimated to be 1.5 months at ambient temperature and 6 months at 4°C. Stability was unaffected by temperature fluctuations during transportation even in cold-chain-free conditions, thus reducing the cost required for cold storage.
Conclusion: The sensitive, cost-effective, ready-to-use, and ambient temperature stable formulation could be implemented as a detection tool in food analysis and diagnostic laboratories and hospitals and for on-field application outside the laboratories, as well as for detection of toxigenic strains of S. aureus.