Objectives: The aims of this study were to evaluate morphological and quantitative 7 T magnetic resonance imaging (MRI) hip sequences in patients after acetabular cartilage transplantation and to compare image quality with 3 T MRI.
Materials And Methods: Following approval from the local institutional ethics committee and signing informed consent, 9 patients with history of autologous acetabular cartilage transplantation were imaged at 7 T and 3 T MRI. Sequences (3-dimensional dual echo steady state, 3-dimensional T1 volume interpolated breath-hold examination, sagittal proton density [PD] turbo spin echo and coronal fat-saturated PD turbo spin echo, sagittal T1 mapping in dual flip angle technique, and multiecho spin echo/gradient echo sequences for T2 and T2* mapping) were applied after the intravenous application of Gd-DTPA according to a protocol for delayed gadolinium-enhanced MRI of cartilage and manual B1 shimming at 7 T. Images were compared intraindividually regarding image quality and assessability of cartilage structures using 5-point scales (1 = 3 T clearly superior, 5 = 7 T clearly superior) in consensus with 2 radiologists. Contrast ratios were calculated between articular cartilage, joint fluid, and subchondral bone. An adapted MOCART (MR observation of cartilage repair tissue) score was assessed independently at 3 T and 7 T. Relaxation times were measured in the transplanted acetabular region and in 2 reference regions by 2 readers independently to calculate interreader reliability. Statistical significances of field strength comparisons were calculated using Student t test and t test for dependent measurements.
Results: A 7 T MRI was superior to 3 T MRI in the majority of the sequences regarding subjective ratings. Furthermore, 7 T yielded comparable or better contrast ratios compared with 3 T. The criteria of the MOCART score matched totally at 3 T and 7 T, apart from the signal intensity of the repair tissue in PDw, which was rated higher at 7 T in 5 patients. Interreader reliability of all relaxation times was excellent. T1 and T2* relaxation times were significantly shorter at 7 T compared with 3 T. T2 relaxation times were longer at 7 T compared with 3 T without statistical significance. No significant difference could be seen when comparing the relaxation ratios (relaxation times after standardization to reference regions) of the cartilage transplant between the 2 field strengths.
Conclusions: This study shows the feasibility of morphological and quantitative 7 T hip MRI in patients after acetabular cartilage transplantation and its predominant superiority regarding image quality, assessment of cartilage transplants, and contrast over 3 T MRI. To compare relaxation times between the field strengths, the calculation of intraindividual ratios is recommended.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/RLI.0000000000000264 | DOI Listing |
Injured epithelial organs must rapidly replace damaged cells to restore barrier integrity and physiological function. In response, injury-born stem cell progeny differentiate faster compared to healthy-born counterparts, yet the mechanisms that pace differentia-tion are unclear. Using the adult Drosophila intestine, we find that injury speeds cell differentiation by altering the lateral inhibition circuit that transduces a fate-determin-ing Notch signal.
View Article and Find Full Text PDFContemp Clin Trials Commun
February 2025
Copenhagen Trial Unit, Centre for Clinical Intervention Research, The Capital Region, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
Background: Research on improving psychotherapy for youths with obsessive-compulsive disorder (OCD), including cognitive behavioral therapy (CBT), should explore what works for whom and how by examining baseline moderators and potential mechanisms of change. Emotion dysregulation is proposed as an intermediate therapy factor in a transdiagnostic framework. This study investigates emotion dysregulation as an outcome, mechanism, and moderator of psychotherapy in youths aged 8-17 years with OCD.
View Article and Find Full Text PDFJ Med Ultrasound
February 2024
Department of Electrical Engineering, Computer Engineering and Informatics, Cyprus University of Technology, Limassol, Cyprus.
Background: The main goal of the study was to find the magnetic resonance imaging (MRI) parameters that optimize contrast between tissue and thermal lesions produced by focused ultrasound (FUS) using T1-weighted (T1-W) and T2-weighted (T2-W) fast spin echo (FSE) sequences.
Methods: FUS sonications were performed in porcine tissue using a single-element FUS transducer of 2.6 MHz in 1.
J Am Chem Soc
January 2025
Department of Chemistry, Graduate School of Science, Kyoto University, Kitashirakawa-Oiwakecho, Sakyo-Ku, Kyoto 606-8502, Japan.
We studied the vibrational coherences during the ultrafast internal conversions (ICs) of pyrimidine nucleobases and -sides in aqueous solutions and the gas phase with an instrumental resolution of 14 fs. The coherence of the same ring-breathing vibrational mode with a frequency of 750 cm was observed. In the gas phase, the vibrational coherence was transferred during IC from the ππ* to the nπ* state, and it survived for approximately 1 ps.
View Article and Find Full Text PDFJ Phys Chem B
January 2025
Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, J. D. Block, Sec.III, Salt Lake, Kolkata, West Bengal 700 098, India.
We investigated the temperature dependence of the intermolecular dynamics, including intermolecular vibrations and collective orientational relaxation, of one of the most typical deep eutectic solvents, reline, using femtosecond Raman-induced Kerr effect spectroscopy (fs-RIKES), subpicosecond optical Kerr effect spectroscopy (ps-OKES), and molecular dynamics (MD) simulations. According to fs-RIKES results, the temperature-dependent intermolecular vibrational band peak at ∼90 cm exhibited a redshift with increasing temperature. The density-of-state (DOS) spectrum of reline by MD simulations reproduced this fs-RIKES spectral feature.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!