Contact-free monitoring of vessel graft stiffness - proof of concept as a tool for vascular tissue engineering.

J Tissue Eng Regen Med

Ostbayerische Technische Hochschule (OTH) Regensburg, FB Maschinenbau, Regensburg, Germany.

Published: October 2017

Tissue-engineered vessel grafts have to mimic the biomechanical properties of native blood vessels. Manufacturing processes often condition grafts to adapt them to the target flow conditions. Graft stiffness is influenced by material properties and dimensions and determines graft compliance. This proof-of-concept study evaluated a contact-free method to monitor biomechanical properties without compromising sterility. Forced vibration response analysis was performed on human umbilical vein (HUV) segments mounted in a buffer-filled tubing system. A linear motor and a dynamic signal analyser were used to excite the fluid by white noise (0-200 Hz). Vein responses were read out by laser triangulation and analysed by fast Fourier transformation. Modal analysis was performed by monitoring multiple positions of the vessel surface. As an inverse model of graft stiffening during conditioning, HUV were digested proteolytically, and the course of natural frequencies (NFs) was monitored over 120 min. Human umbilical vein showed up to five modes with NFs in the range of 5-100 Hz. The first natural frequencies of HUV did not alter over time while incubated in buffer (p = 0.555), whereas both collagenase (-35%, p = 0.0061) and elastase (-45%, p < 0.001) treatments caused significant decreases of NF within 120 min. Decellularized HUV showed similar results, indicating that changes of the extracellular matrix were responsible for the observed shift in NF. Performing vibration response analysis on vessel grafts is feasible without compromising sterility or integrity of the samples. This technique allows direct measurement of stiffness as an important biomechanical property, obviating the need to monitor surrogate parameters. Copyright © 2016 John Wiley & Sons, Ltd.

Download full-text PDF

Source
http://dx.doi.org/10.1002/term.2186DOI Listing

Publication Analysis

Top Keywords

graft stiffness
8
biomechanical properties
8
analysis performed
8
human umbilical
8
umbilical vein
8
natural frequencies
8
contact-free monitoring
4
monitoring vessel
4
graft
4
vessel graft
4

Similar Publications

Introduction: As a result of increased incidence of anterior cruciate ligament (ACL) injury in young athletes, there is a rise in the indications surgical ACL reconstruction procedures. The value of anterolateral ligament (ALL) reconstruction emerges as a proposed solution to prevent graft failures and improve stability in this high demanding category of patients. The purpose of this study is to present our experience with a novel hamstring auto-grafting technique, the single antegrade sling graft (SASG), for combined reconstruction of both ACL and ALL using autologous gracilis (GR) and semitendinosus (ST) grafts utilizing a single femoral tunnel and double tibial tunnels.

View Article and Find Full Text PDF

Background: Obesity and metabolic syndrome (MS) accelerate arterial stiffening, increasing cardiovascular (CV) risk after transplant. BMI is limited by inability to differentiate muscle, fat mass, and fat distribution patterns. The aim of this study was to identify the best anthropometric measure to detect arterial stiffness as assessed by pulse wave velocity (PWV) in a racially diverse pediatric transplant population.

View Article and Find Full Text PDF

Biomechanical assessment of ligament maturation after arthroscopic ligament reconstruction of the anterior talofibular ligament.

Orthop Traumatol Surg Res

January 2025

Department of Orthopedic Surgery, Clinique du Sport, 36 Boulevard Saint-Marcel, 75005 Paris, France.

Background: Many techniques have been described for lateral ankle ligament reconstruction. Although the biomechanical properties of gracilis tendons are different from those of ligaments, the use of a gracilis tendon autograft is a popular option for anatomical reconstruction. Graft maturation and the biomechanical processes over time remain unclear.

View Article and Find Full Text PDF

Introduction: Post-traumatic arthritis of elbow is a crippling condition that frequently develops after a serious joint injury. The condition is characterized by pain, rigidity, and diminished functionality, considerably affecting the quality of life of those impacted. Despite advancements in surgical and conservative management, the optimal treatment strategy remains elusive.

View Article and Find Full Text PDF

Background: The study focuses on the use of multi-parametric ultrasound [gray scale, color Doppler and shear wave elastography (SWE)] to differentiate stable renal allografts from acute graft dysfunction and to assess time-dependent changes in parenchymal stiffness, thereby assessing its use as an efficient monitoring tool for ongoing graft dysfunction. To date, biopsy is the gold standard for evaluation of acute graft dysfunction. However, because it is invasive, it carries certain risks and cannot be used for follow-up monitoring.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!