Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2016.02.042DOI Listing

Publication Analysis

Top Keywords

lens exchange
4
exchange trabecular
4
trabecular microbypass
4
microbypass stent
4
stent surgery
4
surgery treat
4
treat secondary
4
secondary pigmentary
4
pigmentary glaucoma
4
glaucoma 1-piece
4

Similar Publications

Iris retractor-assisted optic capture of a 3-piece intraocular lens.

Am J Ophthalmol Case Rep

December 2024

Capital Health, Trenton, NJ, USA.

Optic capture of a three-piece lens in the absence of posterior capsule support is an effective strategy for stabilizing and sequestering the optic to reduce the risk of dislocation and UGH syndrome compared to sulcus placement. We present a novel technique that facilitates optic capture in the presence of a contracted, fibrotic rhexis opening, while minimizing stress on the zonules by using iris retractors to assist in stabilization and expansion of the rhexis, followed by direct injection of the optic of the lens behind the anterior capsule opening into an optic captured configuration.

View Article and Find Full Text PDF

: To evaluate the visual and refractive outcomes of keratorefractive lenticule extraction (KLEx) surgery and refractive lens exchange (RLE) surgery in moderate to high myopia patients. : A retrospective cohort study was performed, and patients receiving KLEx or RLE surgeries with myopia within -3.00 to -10.

View Article and Find Full Text PDF

Purpose: To elucidate the mechanical properties of the bovine lens cortical membrane (CM), the nuclear membrane (NM) containing cholesterol bilayer domains (CBDs), and whole bovine lenses.

Methods: The total lipids (lipids plus cholesterol) from the cortex and nucleus of a single bovine lens were isolated using the monophasic methanol extraction method. Supported CMs and NMs were prepared from total lipids extracted from the cortex and nucleus, respectively, using a rapid solvent exchange method and probe-tip sonication, followed by the fusion of unilamellar vesicles on a flat, freshly cleaved mica surface.

View Article and Find Full Text PDF

Purpose: The research investigates the efficacy of hydroxypropyl methylcellulose (HPMC) treatment in facilitating the development of compact water droplets on the rear surface of synthetic lenses with capsule imperfections during the process of fluid-air exchange.

Method: This study examined four patients with intraocular lens (IOL) implants and posterior capsule defects who experienced the formation of dense water droplets on the posterior surface following fluid-air exchange. When this occurrence obstructs fundus visualization during surgery, it is recommended to suspend the surgical procedure.

View Article and Find Full Text PDF

Purpose: To evaluate the 12-month rotational stability and outcomes of V4c toric Implantable Collamer Lenses (TICLs) (STAAR Surgical) located at two different lens orientations (horizontal or oblique).

Methods: This retrospective study included a total of 403 eyes with TICL implantation, enrolled between January 2021 and December 2022, that were divided into two groups based on the minimum intended angle off the horizontal axis: horizontal with 263 eyes at an angle ±22.5 degrees or less and oblique with 140 eyes at a minimum intended angle of greater than ±22.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!