Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background And Objective: Transbronchial cryobiopsy (TBCB) is a technique in which frozen samples of lung are obtained using a probe inserted through a bronchoscope. We performed a retrospective study to assess the performance of the TBCB procedure complemented by segmental bronchial blockade using an angioplasty balloon, in terms of diagnostic yield and safety in diffuse parenchymal lung disease (DPLD).
Methods: Data from 100 patients with suspected DPLD (clinical and radiological findings), who underwent TBCB in our institution to establish a definitive diagnosis, were reviewed. In our institution, TBCB is monitored with fluoroscopy and performed under general anaesthesia by a multidisciplinary team (an anaesthesiologist, a pulmonologist and an interventional radiologist). In each patient, four samples were collected using a 2.4-mm distal diameter cryoprobe. To control bleeding, the biopsied segmental bronchus was blocked with a 6-mm diameter angioplasty balloon, inserted over a 0.035-inch angled hydrophilic guidewire. After the cryoextraction, the balloon was inflated for 3 min intervals until bleeding stopped.
Results: Overall, 98% of samples had diagnostic value. In 85% of cases, DPLD was confirmed, while in 7%, cancer was diagnosed. Complications were observed in 16% of the patients: 13 patients developed moderate haemorrhage, and 3 developed pneumothorax.
Conclusion: Transbronchial cryobiopsy had a high diagnostic yield for DPLD. Performing the procedure under fluoroscopy guidance and using angioplasty balloon for selective bronchial blockade achieved a low rate of iatrogenic complications directly associated with the technique.