Study of the Microfocus X-Ray Tube Based on a Point-Like Target Used for Micro-Computed Tomography.

PLoS One

The Key Lab for Opto-electronic Technology & Systems of the Education Ministry of China, ICT Research Center, University of Chongqing, Chongqing, China.

Published: July 2017

For a micro-Computed Tomography (Micro-CT) system, the microfocus X-ray tube is an essential component because the spatial resolution of CT images, in theory, is mainly determined by the size and stability of the X-ray focal spot of the microfocus X-ray tube. However, many factors, including voltage fluctuations, mechanical vibrations, and temperature changes, can cause the size and the stability of the X-ray focal spot to degrade. A new microfocus X-ray tube based on a point-like micro-target in which the X-ray target is irradiated with an unfocused electron beam was investigated. EGS4 Monte Carlo simulation code was employed for the calculation of the X-ray intensity produced from the point-like micro-target and the substrate. The effects of several arrangements of the target material, target and beam size were studied. The simulation results demonstrated that if the intensity of X-rays generated at the point-like target is greater than half of the X-ray intensity produced on the substrate, the X-ray focal spot is determined in part by the point-like target rather than by the electron beam in the conventional X-ray tube. In theory, since it is able to reduce those unfavorable effects such as the electron beam trajectory swinging and the beam size changing for the microfocus X-ray tube, it could alleviate CT image artifacts caused by the X-ray focal spot shift and size change.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4889132PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0156224PLOS

Publication Analysis

Top Keywords

x-ray tube
24
microfocus x-ray
20
x-ray focal
16
focal spot
16
x-ray
13
point-like target
12
electron beam
12
tube based
8
based point-like
8
micro-computed tomography
8

Similar Publications

Purpose: This study evaluated beam quality and radiation dosimetry of a CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO). PVO features miniaturized electronics, a detector cut with microblade technology, and increased filtration in order to increase x-ray detection and reduce image noise.

Methods: We assessed the performance of two similar 320-detector CT scanners: one equipped with PVO and one without.

View Article and Find Full Text PDF

Hemorrhagic pleural effusion as the sole manifestation of pancreatitis is exceedingly rare and often presents diagnostic challenges due to its misleading symptoms. We report the case of an adult male with a large left-sided black pleural effusion secondary to chronic necrotizing pancreatitis. The patient presented with progressive shortness of breath and cough, with a history of alcohol use and a previous diagnosis of acute severe pancreatitis.

View Article and Find Full Text PDF

Efficacy of 4-dimensional hysterosalpingo-contrast sonography and X-ray hysterosalpingography in infertility.

Pak J Med Sci

January 2025

Ruichao Miao Department of Reproductive Center, Qingdao Women and Children's Hospital, Qingdao, Shandong Province 266000, P.R. China.

Objective: To assess and compare efficacy of 4-dimensional hysterosalpingo-contrast sonography (4D-HyCoSy) and X-ray hysterosalpingography (HSG) for fallopian tube examination.

Methods: Clinical data of patients with suspected tubal infertility, who underwent examinations in Qingdao Women and Children's Hospital from September 2021 to December 2023, were retrospectively analyzed. Of them, 40 patients received laparoscopy and dye test+ 4D-HyCoSy (4D-HyCoSy group), and 36 patients received laparoscopy and dye test +HSG (HSG group).

View Article and Find Full Text PDF

Lemmel syndrome involves a periampullary duodenal diverticulum (PAD), a pouch-like outpouching near the ampulla of Vater, compressing the common bile duct. We describe a case of severe abdominal pain in a patient who had a large periampullary diverticulum, managed with surgical intervention after an initial failed endoscopic retrograde cholangiopancreatography (ERCP). An elderly female patient in her early 90s arrived at the emergency department with severe cramping pain localized to the right upper quadrant of her abdomen, progressively intensifying over several weeks.

View Article and Find Full Text PDF

Evaluation of charge summing correction in CdTe-based photon-counting detectors for breast CT: performance metrics and image quality.

J Med Imaging (Bellingham)

January 2025

U.S. Food and Drug Administration, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, Silver Spring, Maryland, United States.

Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).

Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!