A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Baseline-Corrected Second-Order Derivative Electroanalysis Combined With Ultrasound-Assisted Liquid-Liquid Microextraction: Simultaneous Quantification of Fluoroquinolones at Low Levels. | LitMetric

Baseline-Corrected Second-Order Derivative Electroanalysis Combined With Ultrasound-Assisted Liquid-Liquid Microextraction: Simultaneous Quantification of Fluoroquinolones at Low Levels.

Anal Chem

Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados , Rodovia Dourados-Itahum, km 12, Dourados-MS, 79804-970, Brazil.

Published: June 2016

A baseline-corrected second-order derivative procedure and a miniaturized sample preparation based on low-density solvent and ultrasound-assisted liquid-liquid microextraction (LDS-UA-LLME) was combined to provide the simultaneous electroanalysis of three fluoroquinolones (FQ) as emerging contaminants (ECs). The enhanced mathematical processing provided the best separation with an accurate measurement of the overlapping peaks during the simultaneous electro-oxidation of target FQs that were directly dropped on the surface of carbon nanofiber-modified screen-printed electrodes. The adapted LDS-UA-LLME protocol was the key step involved in the sample preparation, which preconcentrate target analytes from diluted tap water samples with an enrichment factor of around 80×, allowing their quantification at trace levels. This combined feature demonstrated the unique application of an electroanalytical technique for the simultaneous electroanalysis of three FQs in spiked tap water samples, with recovery values remarkably close to 100%.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.6b01379DOI Listing

Publication Analysis

Top Keywords

baseline-corrected second-order
8
second-order derivative
8
ultrasound-assisted liquid-liquid
8
liquid-liquid microextraction
8
sample preparation
8
simultaneous electroanalysis
8
electroanalysis three
8
tap water
8
water samples
8
derivative electroanalysis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!