Unsuccessful Treatment of Atrophic Mandible Fracture by Use of Improper Materials.

J Craniofac Surg

*Postgraduate Program in Odontology at UNESP, São Paulo State University †Habilitation in Surgery and Traumatology at Faculty of Dentistry of Araçatuba (UNESP) and Adjunct Professor III, Department of Integrated Clinical and Surgery of São Paulo (UNESP), College of Dentistry Araçatuba, São Paulo ‡Department of Surgery, Faculty of Medical Sciences, Federal University of Mato Grosso-UFMT, Cuiabá §Postgraduate Program in Odontology at UNESP, São Paulo State University, São Paulo ||Residency Program in Maxillofacial Surgery and Traumatology, University of Cuiabá/Hospital General Universitario ¶Professional Masters in Integrated Dental Science, University of Cuiabá-UNIC, Cuiaba, Brazil.

Published: June 2016

Fractures of atrophic mandibles are present on the day by day of buccomaxillofacial surgeons. Mandible atrophy occurs due to tooth loss, which over time induces bone resorption leading to a fragile and susceptible to fracture structure. This paper reports the case of a patient victim of face trauma resulting in atrophic mandible fracture with treatment failure through the use of shared load miniplate. Therefore, a new treatment was performed with miniplate of system 2.4 along with bone graft. After 6 months, the patient was rehabilitated with implant-supported prosthesis installation. It is concluded that for successful treatment of atrophic mandible fractures, the use of rigid plates is necessary, allowing an excellent rehabilitation of the stomatognathic system.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0000000000002640DOI Listing

Publication Analysis

Top Keywords

atrophic mandible
12
treatment atrophic
8
mandible fracture
8
unsuccessful treatment
4
atrophic
4
mandible
4
fracture improper
4
improper materials
4
materials fractures
4
fractures atrophic
4

Similar Publications

The lateral pterygoid muscle (LPM), a critical component of the masticatory muscles, typically comprises upper (SLPM) and lower (ILPM) heads. However, it is essential to note that the LPM's structure is not a constant feature, as the number of bundles and their topography can vary. Moreover, additional heads, such as medial and middle heads, and unique-headed configurations of the LPM have been reported.

View Article and Find Full Text PDF

The authors present two cases of mouth floor hemorrhage consequences of implant placement within the atrophic anterior mandible. In one patient, the implant placement was associated with the guided bone regeneration (GBR) technique. This serious complication has been widely described in the literature, especially in the anterior mandible area.

View Article and Find Full Text PDF

Full-arch implant rehabilitation in extremely atrophic edentulous mandibles is still challenging due to the high risk of fracture and the limited bone availability. The approach proposes using short implants with immediate loading for final prostheses as a treatment option, which offers shorter treatment times and fewer invasive procedures. A 66-year-old female patient with an edentulous mandible and severe alveolar bone resorption was treated with four short implants in the interforaminal area.

View Article and Find Full Text PDF

Minimally invasive approaches for implant-supported overdentures in the atrophied mandible.

Gerodontology

November 2024

Department of Prosthetic Dentistry, University School of Dental Medicine, Martin-Luther-University, Halle-Wittenberg, Halle, Germany.

Objectives: The study compares three minimally invasive approaches for the retention of implant supported mandibular complete dentures, particularly focusing on patient satisfaction.

Background: The McGill Consensus Statement recommends restoration of the edentulous mandible with an overdenture retained on two implants. Alternatively, less invasive treatment concepts with shorter treatment times have been developed for critical cases.

View Article and Find Full Text PDF

The geometry of implants plays a crucial role in the success of All-on-Four treatments for the lower jaw. This study builds upon prior research by evaluating the biomechanical performance of implant-supported prostheses in full-arch fixed dental restorations, specifically focusing on different implant lengths and connection types in cases of mild atrophic resorption of the mandible. Four groups were analyzed using finite element analysis (FEA): We utilized 13 or 18 mm posterior 17-degree tilting implants, each paired with two kinds of abutment connections.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!