Objective: To present a conversion from an anterior cervical discectomy and fusion (ACDF) to cervical arthroplasty in a 40-year-old, active duty member and perform a review of the literature.

Methods: A helicopter pilot in the U.S. Army underwent a three-level ACDF in 2010 at a nonmilitary institution for symptoms of bilateral upper-extremity radiculopathy. His symptoms resolved; however, per regulations, he was grounded. The patient recently presented at our clinic for evaluation of axial neck and intrascapular pain with radiographic evaluation revealing pseudarthrosis at C6-7 with segmental motion without facet joint degeneration. Surgery was performed to remove the existing allograft and replace it with an artificial disc, thus restoring a motion segment.

Results: Postoperative imaging reveals appropriate placement of the artificial disc and range of motion at C6-7 with the patient reporting improvement in neck pain. He has since been granted a waiver to return to active flight status.

Conclusions: Revision of ACDF to arthroplasty is an exceedingly rare procedure with only two cases reported in the literature. Here, the authors demonstrate use of the procedure for a military career-specific application. When facet joint degeneration or ankylosis is absent, restoration of motion can successfully, and safely, be achieved.

Download full-text PDF

Source
http://dx.doi.org/10.7205/MILMED-D-15-00322DOI Listing

Publication Analysis

Top Keywords

cervical arthroplasty
8
anterior cervical
8
cervical discectomy
8
discectomy fusion
8
facet joint
8
joint degeneration
8
artificial disc
8
performance cervical
4
arthroplasty pseudarthrosed
4
pseudarthrosed level
4

Similar Publications

Background: The purpose of this study was to assess impingement-free internal rotation (IR) in a virtual reverse shoulder arthroplasty simulation using a Statistical Shape Model based on scapula size.

Methods: A database of over 10,000 scapulae utilized for preoperative planning for shoulder arthroplasty was analyzed with a Statistical Shape Model to obtain 5 scapula sizes including the mean and 2 standard deviations. For each scapula model, one glenosphere size (33-42 mm) was selected as the best fit based on consensus among 3 shoulder surgeons.

View Article and Find Full Text PDF

Objectives: To identify the rate of fixation failure following femoral neck fracture (FNF) fixation in young adults within a national database.

Methods: Design: Retrospective cohort study.

Setting: National all-payer claims database.

View Article and Find Full Text PDF

Objectives: While rates of post-traumatic osteoarthritis after acetabulum fracture have been thoroughly studied, there has been less emphasis on hip osteoarthritis after pelvic ring injuries. The objective of this study was to determine the frequency of post-traumatic hip osteoarthritis in pelvic ring injury patients. It was hypothesized that more severe pelvic ring injuries would be associated with greater rates of post-traumatic hip osteoarthritis.

View Article and Find Full Text PDF

Low-Demand Cemented Femoral Stem Designs and Revision Risk Following the Hemiarthroplasty Treatment of Geriatric Hip Fracture.

J Am Acad Orthop Surg

January 2025

From the Hawaii Permanente Medical Group, Kaiser Permanente, Honolulu, HI (Okike), the Department of Surgical Outcomes and Analysis, Kaiser Permanente, San Diego, CA (Prentice, Paxton, and Fasig), the San Francisco Orthopaedic Residency Program, San Francisco, CA (Shah), the Permanente Medical Group, Oakland, CA (Grimsrud), and the Washington Permanente Medical Group P.C, Seattle, WA (Chen).

Background: Cemented fixation is recommended in the hemiarthroplasty treatment of geriatric femoral neck fractures. Certain cemented stems have similarly designed "low-demand" counterparts, but it is unclear whether they yield comparable clinical outcomes. The purpose of this study was to evaluate the revision risk associated with two low-demand stems, Summit Basic (DePuy Synthes) and Versys LD/Fx (Zimmer Biomet), in comparison to their standard counterparts, Summit (DePuy Synthes) and Versys Advocate (Zimmer Biomet).

View Article and Find Full Text PDF

Background: The objective of this report is to present a case of two cervical spine artificial discs (Bryan Cervical Disk) that completely disappeared within 6 months as a result of a high-energy trauma more than 10 years after the initial surgery. Implant dislocation is a known complication in artificial cervical disc replacement. However, this report presents the case of an exceptional migration path with esophageal ingrowth and rectal excretion, not only for one artificial disc but for two at different times It highlights the need for long-term follow-up examinations after artificial cervical disc arthroplasty (ACDA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!