Objective: To evaluate the preservation of low frequency residual hearing after cochlear implant surgery using an electrode for atraumatic implantation and complete cochlear stimulation.

Study Design: Retrospective clinical record study.

Setting: Tertiary referral center.

Patients: Fifty-six patients with functional deafness who had undergone cochlear implant surgery and received a Flex electrode (MED-EL GmbH, Innsbruck, Austria) between 2011 and 2014.

Intervention: Audiometric testing was performed before surgery and at the time of initial fitting.

Main Outcome Measure: Change in low frequency residual hearing measured by pure tone audiometry.

Results: Preoperative hearing was relatively poor. After surgery low frequency residual hearing was partially preserved in most cases, however there was a significant hearing loss at all frequencies compared with the preoperative state. In only 23% of all cases complete hearing preservation was observed.

Conclusion: Despite the use of a flexible electrode, complete preservation of low frequency residual hearing can only be achieved in a minority of patients. The use of a full insertion electrode of 28 mm in patients with poor preoperative thresholds does not allow for usable additional hearing at present.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAO.0000000000001089DOI Listing

Publication Analysis

Top Keywords

residual hearing
20
low frequency
16
frequency residual
16
cochlear implant
12
implant surgery
12
preservation low
8
hearing
8
residual
5
surgery
5
hearing outcomes
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!