Prior glaucoma severity staging systems were mostly concerned with visual field function and retinal nerve fiber layer, but did not include intraocular pressure or medications to capture resistance to treatment. We recently introduced a simple index that combines pressure, medications, and visual field damage and applied it to stratify outcomes of trabectome surgery. In the analysis presented here, we combined data of trabectome alone and trabectome with same session cataract surgery to increase testing power and chances of effect discovery. This microincisional glaucoma surgery removes the primary resistance to outflow in glaucoma, the trabecular meshwork, and has been mostly used in mild glaucoma. Traditional glaucoma surgeries have a relatively high complication rate and have been reserved for more advanced disease stages. In the analysis presented here we include our data of trabectome combined with cataract surgery. This is a common practice pattern as both occur in the same age group with increasing frequency. For patients in higher glaucoma index (GI) groups, the intraocular pressure (IOP) reduction was 2.34+/-0.19 mmHg more than those in a GI group one level lower while holding everything else constant. Those who had undergone trabectome combined with phacoemulsification had an IOP reduction that was 1.29+/-0.39 mmHg less compared to those with trabectome alone. No statistically significant difference was found between genders and age groups while holding everything else constant. Hispanics had a 3.81+/-1.08 mmHg greater IOP reduction. Pseudoexfoliation and steroid glaucoma patients had an IOP reduction that was greater by 2.91+/-0.56 and 3.86+/-0.81 mmHg, respectively, than those with primary open angle glaucoma. These results suggest a role for trabectome-mediated ab interno trabeculectomy beyond mild forms of glaucoma. Additionally, the multifactorial glaucoma index demonstrates a role in staging patients when comparing glaucoma surgical modalities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4870993PMC
http://dx.doi.org/10.12688/f1000research.8448.2DOI Listing

Publication Analysis

Top Keywords

iop reduction
16
glaucoma
12
glaucoma severity
8
visual field
8
intraocular pressure
8
pressure medications
8
analysis presented
8
data trabectome
8
cataract surgery
8
trabectome combined
8

Similar Publications

Corneal Stromal Stem Cell-Derived Extracellular Vesicles Attenuate ANGPTL7 Expression in the Human Trabecular Meshwork.

Transl Vis Sci Technol

January 2025

Department of Ophthalmology, Stein Eye Institute, David Geffen School of Medicine, University of California, Los Angeles, CA, USA.

Purpose: Regulating intraocular pressure (IOP), mainly via the trabecular meshwork (TM), is critical in developing glaucoma. Whereas current treatments aim to lower IOP, directly targeting the dysfunctional TM tissue for therapeutic intervention has proven challenging. In our study, we utilized Dexamethasone (Dex)-treated TM cells as a model to investigate how extracellular vesicles (EVs) from immortalized corneal stromal stem cells (imCSSCs) could influence ANGPTL7 and MYOC genes expression within TM cells.

View Article and Find Full Text PDF

Purpose: To compare the surgical outcomes of visco-circumferential-suture-trabeculotomy (VCST) and rigid probe segmental viscotrabeculotomy (VT) in primary open-angle glaucoma (POAG).

Study Design: A prospective randomized controlled study.

Patients And Methods: Patients presenting with POAG and operated upon in Mansoura Ophthalmic Center in Mansoura, Egypt between February 2017 and September 2021 were enrolled.

View Article and Find Full Text PDF

Purpose: To evaluate the efficacy and safety of the Paul Glaucoma Implant (PGI) surgery in patients with secondary glaucomas.

Patients And Methods: Retrospective chart review of adult patients with medically recalcitrant secondary glaucoma who underwent PGI implantation at a single tertiary center between August 2022 and June 2023. The primary outcome measure was surgical success.

View Article and Find Full Text PDF

Purpose: Trabecular micro-bypass devices (TBDs) such as the iStent series (Glaukos Corporation, Laguna Hills, CA), are effective in reducing intraocular pressure (IOP). However, precise placement of TBDs is crucial in achieving surgical efficacy, as device malpositioning may lead to suboptimal IOP reduction. We demonstrate two novel intra-operative signs to aid confirmation of accurate iStent placement, without reliance on imaging technologies.

View Article and Find Full Text PDF

Precis: Glaucoma surgery impacts corneal graft survival differently by procedure type, with GDDs being most effective at reducing intraocular pressure. However, graft survival rates are comparable across trabeculectomy, CPC, and GDDs. Trabeculectomy improves visual acuity best but often requires additional interventions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!