Background And Aims: EUS-guided biliary drainage (EUS-BD) has been offered for more than a decade as an alternative to percutaneous biliary drainage. Multiple approaches have been described. We propose an algorithm for biliary drainage based on patient anatomy. We aim to assess its validity and safety to guide EUS-BD drainage.
Methods: All patients with biliary obstruction who underwent EUS-BD after failed ERCP from July 2011 through November 2015 underwent the drainage procedure according to the novel algorithm and were enrolled in a dedicated prospective registry. Patients with a dilated intrahepatic biliary tree (IHBT) on cross-sectional imaging received an intrahepatic (IH) approach with anterograde biliary stent placement or hepaticogastrostomy stent placement if anterograde placement was not feasible. Patients with a nondilated IHBT on cross-sectional imaging underwent an extrahepatic (EH) approach with a rendezvous (RDV) technique or a transenteric stent placement if the RDV technique was not feasible. If IH drainage was attempted but unsuccessful, conversion to an EH approach was performed.
Results: Fifty-two patients (mean age, 68 ± 12 years; 52% men) were included in the registry. Technical success was achieved in 50 patients (96%). Twenty-seven of 52 patients (52%) underwent IH anterograde stent placement, 8 of 52 (15%) underwent hepaticogastrostomy, 11 of 52 (21%) underwent EH drainage with the RDV technique, and 6 of 52 (12%) underwent EH drainage with transenteric stent placement. Adverse events were observed in 5 patients (10%) and included a liver abscess requiring percutaneous drainage (n = 1) and bleeding (n = 4) with 1 postprocedural death secondary to bleeding.
Conclusions: EUS-BD obstruction after failed conventional ERCP is successful and safe when this novel algorithm is used. (Clinical trial registration number: NCT01438385.).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.gie.2016.05.035 | DOI Listing |
Am J Case Rep
December 2024
Department of Radiology, University of Tennessee Medical Center-Knoxville, Knoxville, TN, USA.
BACKGROUND Emphysematous urinary tract infections are rare and serious conditions that are often multifactorial in etiology and may be associated with the presence of renal stones. Diagnosis can be made by finding gas within the renal collecting system or parenchyma. However, the radiographic finding of gas within a renal stone is rare and little has been published to describe the significance of this finding, its promoting factors, and management.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Children's Heart Institute, Children's Memorial Hermann Hospital, Houston, Texas.
A patient with known pulmonary atresia and intact ventricular septum and ductal stent presented with low cardiac output and arrythmia. Intraoperatively, the patient was found to have an anomalous left coronary artery arising from the pulmonary artery. After reimplantation of the left coronary artery to the aortic root and placement of a central shunt, the patient progressed well and was discharged home.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.
Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.
View Article and Find Full Text PDFBMC Gastroenterol
January 2025
Division of Gastroenterology, Department of Internal Medicine, Showa University Fujigaoka Hospital, Yokohama, Kanagawa, Japan.
Background: Endoscopic ultrasound-guided transmural drainage (EUS-TD) is widely performed to treat postoperative peripancreatic fluid collection (POPFC). Recent reports on EUS-TD lack a consensus on stent selection. This study aimed to assess the efficacy of EUS-TD for POPFC using an external drainage-based approach.
View Article and Find Full Text PDFActa Neurochir (Wien)
January 2025
Division of Neurosurgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street , Boston, MA, 02215, USA.
Background: Variability in long-term endovascular treatment outcomes for intracranial aneurysms has prompted questions regarding the effects of these treatments on aneurysm hemodynamics. Endovascular techniques disrupt aneurysmal blood flow and shear, but their influence on intra-aneurysmal pressure remains unclear. A better understanding of aneurysm pressure effects may aid in predicting outcomes and guiding treatment decisions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!