AI Article Synopsis

  • A novel method combining gas chromatography with atmospheric pressure chemical ionization mass spectrometry (GC/APCI/MS/MS) was developed to effectively measure organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs).
  • The technique demonstrated high precision, with a relative standard deviation (RSD) of less than 15% and strong calibration results (r² > 0.995), highlighting its reliability for low concentration measurements (0.04 to 300 pg/μL).
  • GC/APCI/MS/MS showed better sensitivity compared to GC coupled with high-resolution mass spectrometry (GC/HRMS) for most compounds tested, proving to be a suitable and efficient alternative for environmental analysis in accordance with international

Article Abstract

A method using a novel atmospheric pressure chemical ionization source for coupling gas chromatography (GC/APCI) to triple quadrupole mass spectrometry (MS/MS) for the determination of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) regulated by the Stockholm Convention is presented. One microliter injection of a six-point calibration curve of native PCBs and OCPs, ranging from 0.04 to 300pg/μL, was performed. The relative standard deviation (RSD) of the relative response factors (RRFs) was less than 15% with a coefficient of determination (r(2))>0.995. Meanwhile, two calibration solutions (CS), CS 2 (0.4pg/μL) and CS 3 (4pg/μL) were analyzed to study the repeatability calculated for both area and RRFs. The RSD for RRF ranged from 3.1 to 16% and 3.6 to 5.5% for CS 2 and CS 3, respectively. The limits of detection (LOD) determined by peak-to-peak signal-to-noise ratio (S/N) of 3 were compared between the GC/APCI/MS/MS and a GC coupled to high resolution mass spectrometry (GC/HRMS) system. GC/APCI/MS/MS resulted in lower LOD for most of the compounds, except for PCB#74, cis-chlordane and trans-chlordane. GC/APCI/MS/MS and GC/HRMS were also compared by performing analysis on 75 human serum samples together with eight QA/QC serum samples. The comparison between GC/APCI/MS/MS system and GC/HRMS system for 16 of the targeted compounds was carried out. No statistically significant difference was discovered. Due to increased sensitivity and user friendly operation under atmospheric pressure, GC/APCI/MS/MS is a powerful alternative technique that can easily meet the specification of GC/HRMS.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2016.05.030DOI Listing

Publication Analysis

Top Keywords

pressure chemical
8
organochlorine pesticides
8
polychlorinated biphenyls
8
human serum
8
atmospheric pressure
8
mass spectrometry
8
gc/hrms system
8
serum samples
8
gc/apci/ms/ms
5
gas chromatography/atmospheric
4

Similar Publications

High-Pressure Refrigerant Gas Injection Injury to the Hand.

J Am Acad Orthop Surg Glob Res Rev

January 2025

From the Department of Orthopaedics and Sports Medicine, Mercy Health St. Vincent Medical Center, Toledo, OH (Dr. Simmons); the Department of Orthopedic Surgery, University Hospitals Cleveland Medical Center, Cleveland, OH (Dr. Vesselle); the Department of Orthopaedic Surgery, MetroHealth Medical Center, Cleveland, OH (Dr. Yildirim, Dr. Bafus); the Town Center Orthopaedics, Reston, VA (Dr. Yildirim); and the Louis Stokes Cleveland VA Medical Center, Cleveland, OH (Dr. Bafus).

High-pressure injection injuries, although rare, are commonly discussed orthopaedic surgical emergencies. In many cases, high-pressure injection injuries can have detrimental effects on the patient. However, there are rare instances where surgical intervention may be more harmful than helpful.

View Article and Find Full Text PDF

Zwitterionic energetic materials offer a unique combination of high performance and stability, yet their synthesis and stability enhancement remain key challenges. In this study, we report the synthesis of a highly stable (dinitromethyl-functionalized zwitterionic compound, 1-(amino(iminio)methyl)-4,5-dihydro-1H-pyrazol-5-yl)dinitromethanide (), with a thermal decomposition temperature of 215 °C, surpassing that of most previously reported energetic monocyclic zwitterions ( < 150 °C). This compound was synthesized via intramolecular cyclization of a trinitromethyl-functionalized hydrazone precursor.

View Article and Find Full Text PDF

Self-Assembling of Multilayered Polymorphs with Ion Beams.

Nano Lett

January 2025

Department of Physics, Centre for Materials Science and Nanotechnology, University of Oslo, PO Box 1048 Blindern, N-0316 Oslo, Norway.

Polymorphism determines significant variations in materials' properties by lattice symmetry variation. If they are stacked together into multilayers, polymorphs may work as an alternative approach to the sequential deposition of layers with different chemical compositions. However, selective polymorph crystallization during conventional thin film synthesis is not trivial; changes of temperature or pressure when switching from one polymorph to another during synthesis may cause degradation of the structural quality.

View Article and Find Full Text PDF

The fluorescence detection of amino compounds and the evaluation of their content in environmental samples are vital, not only for assessing food quality but also for studying soil organic matter. Here, we present the synthesis and application of a novel fluorescent probe, 4-(9-acridone)benzylmethyl carbonochloride (APE-Cl), for detecting amino compounds via a chloroformate reaction with fluorescence detection. The complete derivatization reaction of APE-Cl with amino compounds can be accomplished in aqueous acetonitrile within 5 min at room temperature, using 0.

View Article and Find Full Text PDF

Re-thinking the link between exposure to mercury and blood pressure.

Arch Toxicol

January 2025

Chemical and Environmental Toxicology Program, Department of Biology, University of Ottawa, 30 Marie Curie, Ottawa, ON, K1N 6N5, Canada.

Hypertension or high blood pressure (BP) is a prevalent and manageable chronic condition which is a significant contributor to the total global disease burden. Environmental chemicals, including mercury (Hg), may contribute to hypertension onset and development. Hg is a global health concern, listed by the World Health Organization (WHO) as a top ten chemical of public health concern.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!