Purpose: The purpose of this study was to describe and evaluate the clinical application of the technique of interlocking intramedullary (IM) nailing via an entry point at the tip of greater trochanter using a specially designed femoral hollow trephine to stabilize diaphyseal fractures of the femur.

Methods: From February 2010 to April 2014, 35 consecutive patients with femoral shaft fractures were treated by the therapy of bone grafting from trochanter region with interlocking IM nail. The average age of these 23 male and 12 female patients was 37.5 years (range, 22-67 years). Fractures were classified according to AO classification system (15 type A, 17 type B, 3 type C). Femoral canal reaming and the collection of cancellous bone were simultaneously performed in a single step with the specially designed femoral hollow trephine, followed by regular IM nailing procedure.

Results: Of the 35 cases, the mean volume of spongy bone obtained was 5.63 cm (range, 3.0-7.0 cm). Thirty-five patients with femoral shaft fractures had a mean follow-up period of 16.2 months (range, 12-22 months). All patients achieved bony union, at a mean of 5.4 months (range, 4-6 months). No patient developed a delayed union or a nonunion. There were no complications such as infections, injury of vascular and nerve, or heterotopic ossification in hip.

Conclusions: These results indicate that the technique of use of IM nailing with the femoral hollow trephine significantly decreases the occurrence of nonunion in femoral shaft fractures.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00264-016-3207-2DOI Listing

Publication Analysis

Top Keywords

femoral hollow
16
hollow trephine
16
femoral shaft
16
shaft fractures
16
femoral
9
interlocking intramedullary
8
bone grafting
8
grafting trochanter
8
clinical application
8
specially designed
8

Similar Publications

Background: The management of Garden IV femoral neck fractures presents a formidable challenge. This study aimed to assess the safety and efficacy of a novel technological approach for treating Garden IV femoral neck fractures, involving intracapsular decompression and the utilization of supported hollow screws.

Methods: Between October 2018 and October 2021, a cohort of 46 patients, comprising 25 males and 21 females, was admitted for Garden IV femoral neck fractures.

View Article and Find Full Text PDF

Introduction: The development of pneumatic shooting has led to the construction of technologically advanced devices with discharge energies similar to those of firearms. The pneumatic weapons ammunition market offers a variety of shot which varies in penetration properties and the extent of gunshot damage. In view of the ease of "tuning" of air rifles, a study was conducted of the inlet damage to the anterior femoral surface after pneumatic gunshots.

View Article and Find Full Text PDF

Introduction: In accordance with the Polish law, pneumatic weapons are weapons that use compressed gas to set a bullet in motion and generate a discharge energy of more than 17J. In recent years, Poland has seen an increase in crimes committed with pneumatic weapons. The research aim of the present study was to measure the velocity of selected 5.

View Article and Find Full Text PDF

Background: The present video article describes the revision of a bone-anchored prosthesis in patients who received an osseointegration implant after transfemoral amputation. Clinical follow-up studies have shown that approximately 5% of all patients who receive press-fit cobalt-chromium alloy femoral implants experience failure of the intramedullary stem component as a result of septic loosening or stem breakage. For stem breakage, stem diameter and the occurrence of infectious events were identified as risk factors.

View Article and Find Full Text PDF

This study aimed to retrospectively analyze the follow-up results of cases in which the adjacent joint was preserved using a custom-made uncemented short-stem design (hollow stem) with optional external flanches in tumor endoprosthetic replacement due to bone sarcomas in 13 patients (with an average age of 9.6 years) between 2017 and 2023. Reconstructions were proximal femur ( = 6), intercalary femur ( = 4), intercalary tibia ( = 2), and proximal humerus ( = 1) tumor prostheses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!