Optical Assessment of Soft Contact Lens Edge-Thickness.

Optom Vis Sci

*PhD †BS ‡PhD, MBA The Institute of Optics (PT, JPR), Center for Visual Science (PT, IC, JPR), Department of Biomedical Engineering (JW, JPR), University of Rochester, Rochester, New York; LighTopTech Corp., West Henrietta, New York (CC, JPR); and IGC Consulting, New York, New York (IC).

Published: August 2016

Purpose: To assess the edge shape of soft contact lenses using Gabor-Domain Optical Coherence Microscopy (GD-OCM) with a 2-μm imaging resolution in three dimensions and to generate edge-thickness profiles at different distances from the edge tip of soft contact lenses.

Methods: A high-speed custom-designed GD-OCM system was used to produce 3D images of the edge of an experimental soft contact lens (Bausch + Lomb, Rochester, NY) in four different configurations: in air, submerged into water, submerged into saline with contrast agent, and placed onto the cornea of a porcine eyeball. An algorithm to compute the edge-thickness was developed and applied to cross-sectional images. The proposed algorithm includes the accurate detection of the interfaces between the lens and the environment, and the correction of the refraction error.

Results: The sharply defined edge tip of a soft contact lens was visualized in 3D. Results showed precise thickness measurement of the contact lens edge profile. Fifty cross-sectional image frames for each configuration were used to test the robustness of the algorithm in evaluating the edge-thickness at any distance from the edge tip. The precision of the measurements was less than 0.2 μm.

Conclusions: The results confirmed the ability of GD-OCM to provide high-definition images of soft contact lens edges. As a nondestructive, precise, and fast metrology tool for soft contact lens measurement, the integration of GD-OCM in the design and manufacturing of contact lenses will be beneficial for further improvement in edge design and quality control. In the clinical perspective, the in vivo evaluation of the lens fitted onto the cornea will advance our understanding of how the edge interacts with the ocular surface. The latter will provide insights into the impact of long-term use of contact lenses on the visual performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4961562PMC
http://dx.doi.org/10.1097/OPX.0000000000000892DOI Listing

Publication Analysis

Top Keywords

soft contact
28
contact lens
24
contact lenses
12
contact
10
lens
8
edge
8
edge soft
8
soft
7
optical assessment
4
assessment soft
4

Similar Publications

We report on the U-shaped folding of flexible guest molecules of medicinal interest upon their inclusion into macrocyclic cavity of p-sulfonato-calix[4]arene in aqueous media. Alexidine and pentamidine are FDA-approved drug compounds currently rediscovered as potent membrane-targeting antibiotic adjuvants helping restore antibiotic activity against multidrug resistant bacteria pathogens. We have adopted host-guest and crystal engineering approach to study these drugs with a view of potential supramolecular formulations and/or crystal forms.

View Article and Find Full Text PDF

Background: Orthokeratology (OK) contact lenses are increasingly prescribed for myopia control but their impact on corneal epithelial immune cells (CEIC) is unclear. This study compares CEIC in OK wearers to soft contact lens (SCL) wearers and non-wearers.

Methods: In vivo confocal microscope images at the corneal central and mid-peripheral subbasal level were evaluated in 18 OK wearers, 18 SCL wearers and 18 non-wearers (mean age 27.

View Article and Find Full Text PDF

Liquid slide electrification: advances and open questions.

Soft Matter

January 2025

Institute for Photovoltaics, University of Stuttgart, Pfaffenwaldring 47, 70569 Stuttgart, Germany.

This review is about drops of a liquid with high dielectric permittivity that slide over a solid surface with high electrical resistivity. A typical situation is a water drop sliding down a tilted hydrophobic plate. It has been realized recently that such drops spontaneously acquire a charge.

View Article and Find Full Text PDF

Introduction: Accurate prediction of knee biomechanics during total knee replacement (TKR) surgery is crucial for optimal outcomes. This study investigates the application of machine learning (ML) techniques for real-time prediction of knee joint mechanics.

Methods: A validated finite element (FE) model of the lower limb was used to generate a dataset of knee joint kinematics, kinetics, and contact mechanics.

View Article and Find Full Text PDF

The ability to convert moisture signals into electrical signals through contactless control underpins a wide range of applications, including health monitoring, disaster warning, and energy harvesting. Despite its potential, the effective utilization of low-grade energy remains challenging, as it often requires complex device architectures that limit scalability and integration, particularly in wearable technologies. Here, we present a soft, flexible moisture-electric converter made from cellulose nanocrystals and polyvinyl alcohol composite films, designed for a novel touchless interactive platform.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!