Sixteen patients with coronary artery fistula proved by coronary angiography or surgery were studied using two-dimensional echocardiography and Doppler color flow mapping. The coronary artery fistula drained into the right atrium in 4 patients, the right ventricle in 2 and the pulmonary artery in 10. The dilated coronary artery was visualized in 7 of the 16 patients with a fistula, as compared with none of the 40 control subjects. These 7 patients included 5 of 6 patients with a fistula draining into the right atrium or right ventricle and only 2 of 10 patients with a fistula draining into the pulmonary artery. Abnormal flow signals in the dilated coronary artery were visualized with Doppler color flow mapping in five of these seven patients. Color flow imaging visualized abnormal flow signals with mosaic appearance in the pulmonary artery in eight patients, the right atrium in four and the right ventricle in two. The chamber in which abnormal signals were detected corresponded with the entry site of the fistula by angiography. Intraoperative imaging during surgical repair was needed in two cases to confirm ligation of all arteries feeding into the fistula network. In conclusion, Doppler color flow imaging is diagnostically useful to visualize shunt flows originating from the opening or exit of a coronary artery fistula. Furthermore, intraoperative use of this technique may provide confirmation of successful surgical ligation of the fistula.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0735-1097(89)90351-3DOI Listing

Publication Analysis

Top Keywords

coronary artery
24
color flow
20
artery fistula
16
doppler color
16
flow mapping
12
pulmonary artery
12
patients fistula
12
fistula
10
artery
9
patients
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!