OBJECTIVE Several biomechanical studies have demonstrated the favorable mechanical properties of the cortical bone trajectory (CBT) screw. However, no reports have examined surgical outcomes of posterior lumbar interbody fusion (PLIF) with CBT screw fixation for degenerative spondylolisthesis (DS) compared with those after PLIF using traditional pedicle screw (PS) fixation. The purposes of this study were thus to elucidate surgical outcomes after PLIF with CBT screw fixation for DS and to compare these results with those after PLIF using traditional PS fixation. METHODS Ninety-five consecutive patients underwent PLIF with CBT screw fixation for DS (CBT group; mean followup 35 months). A historical control group consisted of 82 consecutive patients who underwent PLIF with traditional PS fixation (PS group; mean follow-up 40 months). Clinical status was assessed using the Japanese Orthopaedic Association (JOA) scale score. Fusion status was assessed by dynamic plain radiographs and CT. The need for additional surgery and surgery-related complications was also evaluated. RESULTS The mean JOA score improved significantly from 13.7 points before surgery to 23.3 points at the latest follow-up in the CBT group (mean recovery rate 64.4%), compared with 14.4 points preoperatively to 22.7 points at final follow-up in the PS group (mean recovery rate 55.8%; p < 0.05). Solid spinal fusion was achieved in 84 patients from the CBT group (88.4%) and in 79 patients from the PS group (96.3%, p > 0.05). Symptomatic adjacent-segment disease developed in 3 patients from the CBT group (3.2%) compared with 9 patients from the PS group (11.0%, p < 0.05). CONCLUSIONS PLIF with CBT screw fixation for DS provided comparable improvement of clinical symptoms with PLIF using traditional PS fixation. However, the successful fusion rate tended to be lower in the CBT group than in the PS group, although the difference was not statistically significant between the 2 groups.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2016.3.SPINE151525DOI Listing

Publication Analysis

Top Keywords

screw fixation
28
cbt screw
20
cbt group
20
plif cbt
16
plif traditional
16
posterior lumbar
12
lumbar interbody
12
interbody fusion
12
traditional fixation
12
group
11

Similar Publications

Introduction: We propose and assess the biomechanical stability of medial column screw supplementation in a synthetic distal femur fracture model.

Materials And Methods: Twenty-four low density synthetic femora modeling osteoporotic, intraarticular distal femur fractures with medial metaphyseal comminution were split into two fixation groups: (1) lateral locking distal femur plate (PA- plate alone) and (2) lateral locking distal femur plate with a 6.5 mm fully threaded medial cannulated screw (PWS- plate with screw).

View Article and Find Full Text PDF

Background: Fixation of distal femoral fractures remains a challenge, and nonunions are common with standard constructs. Far cortical locking (FCL) constructs have been purported to lead to improved fracture-healing as compared with that achieved with traditional locking bridge plates. We sought to test this hypothesis in a comparative effectiveness clinical trial.

View Article and Find Full Text PDF

This study compares the compression force of cortical screws used in lag fashion with partially threaded cannulated screws and fully threaded headless cannulated screws as fixation methods for humeral condylar fractures in dogs. Cadavers of eleven dogs weighing an average of 10.99 ± 2.

View Article and Find Full Text PDF

(1) Background: The incidence of fragility fractures of the pelvis (FFP) has increased significantly over the past decades. Unilateral non-displaced fractures, defined as FFP II, are the most common type of fracture. When conservative treatment fails, surgical treatment is indicated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!