We introduce, validate and demonstrate a new software correlator for high-speed measurement of blood flow in deep tissues based on diffuse correlation spectroscopy (DCS). The software correlator scheme employs standard PC-based data acquisition boards to measure temporal intensity autocorrelation functions continuously at 50 - 100 Hz, the fastest blood flow measurements reported with DCS to date. The data streams, obtained in vivo for typical source-detector separations of 2.5 cm, easily resolve pulsatile heart-beat fluctuations in blood flow which were previously considered to be noise. We employ the device to separate tissue blood flow from tissue absorption/scattering dynamics and thereby show that the origin of the pulsatile DCS signal is primarily flow, and we monitor cerebral autoregulation dynamics in healthy volunteers more accurately than with traditional instrumentation as a result of increased data acquisition rates. Finally, we characterize measurement signal-to-noise ratio and identify count rate and averaging parameters needed for optimal performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4866455PMC
http://dx.doi.org/10.1364/BOE.7.000776DOI Listing

Publication Analysis

Top Keywords

blood flow
20
deep tissues
8
software correlator
8
data acquisition
8
flow
6
fast blood
4
flow monitoring
4
monitoring deep
4
tissues real-time
4
real-time software
4

Similar Publications

Objective: To investigate the role of endoscopic ultrasonography (EUS) in the diagnosis and treatment of upper gastrointestinal bleeding of unknown origin in liver cirrhosis, focusing on patients with recurrent treatment of esophageal and gastric varices who failed to identify the bleeding site under direct endoscopy.

Background: Esophagogastric variceal bleeding is one of the severe complications of decompensated liver cirrhosis, and serial endoscopic therapy can improve the long-term quality of life of patients. Most acute bleeding can be detected under direct endoscopy with thrombus or active bleeding, but there are still some patients with recurrent bleeding after repeated treatments, and it is difficult to find the bleeding site, especially in gastric variceal bleeding.

View Article and Find Full Text PDF

Can ACR TI-RADS predict the malignant risk of medullary thyroid cancer?

J Clin Transl Endocrinol

March 2025

Department of Ultrasound, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai 200072, PR China.

Objectives: This study aimed to evaluate the diagnostic performance for medullary thyroid cancer (MTC) based on the 2017 Thyroid Imaging Reporting and Data System by the American College of Radiology (ACR TI-RADS) guideline, and the ability to recommend fine needle aspiration (FNA) for MTC.

Methods: Fifty-six MTCs were included, and 168 benign thyroid nodules (BTNs) and 168 papillary thyroid nodules (PTCs) were matched according to age. Ultrasound (US) features were reviewed according to ACR TI-RADS.

View Article and Find Full Text PDF

Total pharyngo-laryngo-esophagectomy (TPLE) with free jejunal transplantation (FJT) is the standard reconstructive procedure for hypopharyngeal cancer, typically utilizing the superior thyroid artery as the recipient vessel. However, patient-specific anatomical variations and comorbidities can significantly complicate this surgery. We present a unique case of a 68-year-old male with hypopharyngeal cancer who exhibited multiple challenges, including short stature (126 cm), low weight (35 kg), cervical spondylosis, and a history of vertebroplasty, highlighting the complexities inherent in such reconstructions.

View Article and Find Full Text PDF

Background: TG02 is a peptide-based cancer vaccine eliciting immune responses to oncogenic codon 12/13 mutations. This phase 1 clinical trial (NCT02933944) assessed the safety and immunological efficacy of TG02 adjuvanted by GM-CSF in patients with -mutant colorectal cancer.

Methods: In the interval between completing CRT and pelvic exenteration, patients with resectable mutation-positive, locally advanced primary or current colorectal cancer, received 5-6 doses of TG02/GM-CSF.

View Article and Find Full Text PDF

Objective: To investigate the short-term blood flow changes and image features of the retina and choroid in patients who underwent carotid artery revascularization (CAR) for severe carotid artery stenosis using widefield swept-source OCT angiography (OCTA).

Design: Prospective study.

Participants: This prospective study included 112 eyes (56 eyes on the ipsilateral side and 56 eyes on the contralateral side) of 56 participants with severe carotid artery stenosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!