A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of Novel RP-HPLC Method for Separation and Estimation of Critical Geometric Isomer and Other Related Impurities of Tafluprost Drug Substance and Identification of Major Degradation Compounds by Using LC-MS. | LitMetric

A novel, simple, sensitive and stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the quantitative determination of the geometric isomer (Trans) and other related substances in the active pharmaceutical ingredient (API) of Tafluprost (TFL), with their determination by an assay. A chromatographic separation of TFL and its impurities was achieved with a C18 analytical column, using gradient elution with mobile phase A consisting of a mixture of water, methanol and orthophosphoric acid (900:100:1, v/v) and mobile phase B consisting of a mixture of acetonitrile and water (900:100, v/v). The instrumental settings included a flow rate of 1.0 mL/min for related substances and 1.2 mL/min for the assay, a column temperature of 50°C and a detector wavelength of 210 nm, using a photodiode array detector. TFL was exposed to thermal, photolytic, hydrolytic and oxidative stress conditions and the stressed samples were analyzed by the proposed method. Peak homogeneity data of TFL were obtained by using a photodiode array detector in the stressed sample chromatograms, which demonstrated the specificity of the method for estimation in the presence of degradants. The developed method was validated for parameters such as precision, accuracy, linearity, limit of detection, limit of quantification, ruggedness and robustness as per ICH guidelines.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmw086DOI Listing

Publication Analysis

Top Keywords

rp-hplc method
8
geometric isomer
8
mobile phase
8
phase consisting
8
consisting mixture
8
photodiode array
8
array detector
8
method
5
development novel
4
novel rp-hplc
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!