A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hb Grifton [α87(F8)His→Pro; HBA1: C.263A > C (or HBA2)] Causes Abnormal Pulse Oximetry Measurements. | LitMetric

An asymptomatic toddler and his mother consistently demonstrated low transcutaneous pulse oximetry (SpO2) measurements, discordant with normal arterial blood gas analyses while breathing room air. Previous evaluations by medical teams were unable to identify an etiology of their perceived hypoxia. Further investigation revealed that the boy carried an abnormal variant, Hb Grifton or α87(F8)His→Pro; HBA1: c.263A > C (or HBA2), discovered on newborn screening, which was not suspected as the underlying cause of his abnormal pulse oximetry readings until an inpatient admission to our hospital for asymptomatic "hypoxia," where he was found to share these same characteristics with his mother. We showed that a difference in light absorption between the oxygenated Hb Grifton variant and oxygenated Hb A resulted in erroneous pulse oximetry values. This phenomenon has previously been reported in a handful of other variant Hbs. Astute clinical suspicion, in conjunction with laboratory testing leading to correct diagnoses of variant Hbs, may prevent expensive work-ups and unnecessary medical treatments for asymptomatic patients falsely presumed to be hypoxemic based on low pulse oximetry measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1080/03630269.2016.1174872DOI Listing

Publication Analysis

Top Keywords

pulse oximetry
20
hba1 c263a > c
8
abnormal pulse
8
oximetry measurements
8
variant hbs
8
pulse
5
oximetry
5
grifton [α87f8his→pro
4
[α87f8his→pro hba1
4
c263a > c hba2]
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!