Major surgical procedures often result in significant intra- and postoperative bleeding. The ability to identify the cause of the bleeding has the potential to reduce the transfusion of blood products and improve patient care. We present a novel device, the Quantra Hemostasis Analyzer, which has been designed for automated, rapid, near-patient monitoring of hemostasis. The Quantra is based on Sonic Estimation of Elasticity via Resonance Sonorheometry, a proprietary technology that uses ultrasound to measure clot time and clot stiffness from changes in viscoelastic properties of whole blood during coagulation. We present results of internal validation and analytical performance testing of the technology and demonstrate the ability to characterize the key functional components of hemostasis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5536171PMC
http://dx.doi.org/10.1213/ANE.0000000000001413DOI Listing

Publication Analysis

Top Keywords

novel device
8
device evaluation
4
evaluation hemostatic
4
hemostatic function
4
function critical
4
critical care
4
care settings
4
settings major
4
major surgical
4
surgical procedures
4

Similar Publications

Background: Oxygen therapy is critical and vital treatment for hypoxemia and respiratory distress, however, access to reliable oxygen systems remains limited in SSA. Despite WHO initiatives that distributed over 30,000 OC oxygen concentrators worldwide, SSA faces significant challenges related to their maintenance and use, due to harsh environmental conditions, technical skill shortages and inadequate infrastructure. This review aims to systematically identify and assess the literature on OC design adaptations, maintenance challenges, and knowledge gaps in SSA, providing actionable recommendations to inform innovative and context-sensitive solutions to improve healthcare delivery in the region.

View Article and Find Full Text PDF

Background: Workplace health screening rarely includes measures of cardiorespiratory fitness, despite it being a greater predictor of cardiovascular disease and all-cause mortality than other routinely measured risk factors. This study aimed to determine the comparative acceptability of using a novel seismocardiography device to measure cardiorespiratory fitness via VO max during a workplace health check.

Methods: Participants were invited to participate in workplace health screening sessions where VO max was assessed by both seismocardiography at rest and sub-maximal exercise testing, in order for acceptability of both to be compared across multiple domains.

View Article and Find Full Text PDF

Background: Shake flasks are essential tools in biotechnological development due to their cost efficiency and ease of use. However, a significant challenge is the miniaturization of process analytical tools to maximize information output from each cultivation. This study aimed to develop a respiration activity online measurement system via off-gas analysis, named "Transfer rate Online Measurement" (TOM), for determining the oxygen transfer rate (OTR), carbon dioxide transfer rate (CTR), and the respiration quotient (RQ) in surface-aerated bioreactors, primarily targeting shake flasks.

View Article and Find Full Text PDF

A ratiometric fluorescent nanoprobe (CDs-Rho), synthesized through the simple covalent amide linkage between carbon dots (CDs) and pH-sensitive rhodamine dye (Rho), was designed for the precise sensing and imaging of extremely alkaline environments. The sensing mechanism involves the opposite pH-dependent fluorescence changes in CDs and Rho, respectively, coupled with pH-regulated FRET efficiency from CDs to Rho. The nanoprobe features a wide pH response window from pH 7.

View Article and Find Full Text PDF

A novel separated OPECT aptasensor based on MOF-derived BiVO/BiS type-II heterojunction for rapid detection of bacterial quorum sensing signal molecules.

Talanta

January 2025

Qingdao Key Laboratory of Analytical Technology Development and Offshore Eco-Environment Conservation, Marine Bioresource and Environment Research Center, First Institute of Oceanography, Ministry of Natural Resources, No. 6 Xianxialing Road, Qingdao, 266061, PR China. Electronic address:

Quorum sensing signal molecules released by microorganisms serve as critical biomarkers regulating the attachment and aggregation of marine microbes on engineered surfaces. Hence, the development of efficient and convenient methods for detecting quorum sensing signal molecules is crucial for monitoring and controlling the formation and development of marine biofouling. Advanced optoelectronic technologies offer increased opportunities and methods for detecting quorum sensing signal molecules, thereby enhancing the accuracy and efficiency of detection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!