Ultrasound assessment for grading structural tendon changes in supraspinatus tendinopathy: an inter-rater reliability study.

BMJ Open

Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark Department of Health Sciences, Institute of Occupational Therapy, Physiotherapy and Radiography, Bergen University College, Bergen, Norway.

Published: May 2016

Aim: To evaluate the inter-rater reliability of measuring structural changes in the tendon of patients, clinically diagnosed with supraspinatus tendinopathy (cases) and healthy participants (controls), on ultrasound (US) images captured by standardised procedures.

Methods: A total of 40 participants (24 patients) were included for assessing inter-rater reliability of measurements of fibrillar disruption, neovascularity, as well as the number and total length of calcifications and tendon thickness. Linear weighted κ, intraclass correlation (ICC), SEM, limits of agreement (LOA) and minimal detectable change (MDC) were used to evaluate reliability.

Results: 'Moderate-almost perfect' κ was found for grading fibrillar disruption, neovascularity and number of calcifications (k 0.60-0.96). For total length of calcifications and tendon thickness, ICC was 'excellent' (0.85-0.90), with SEM(Agreement) ranging from 0.63 to 2.94 mm and MDC(group) ranging from 0.28 to 1.29 mm. In general, SEM, LOA and MDC showed larger variation for calcifications than for tendon thickness.

Conclusions: Inter-rater reliability was moderate to almost perfect when a standardised procedure was applied for measuring structural changes on captured US images and movie sequences of relevance for patients with supraspinatus tendinopathy. Future studies should test intra-rater and inter-rater reliability of the method in vivo for use in clinical practice, in addition to validation against a gold standard, such as MRI.

Trial Registration Number: NCT01984203; Pre-results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4885468PMC
http://dx.doi.org/10.1136/bmjopen-2016-011746DOI Listing

Publication Analysis

Top Keywords

inter-rater reliability
20
supraspinatus tendinopathy
12
calcifications tendon
12
measuring structural
8
structural changes
8
fibrillar disruption
8
disruption neovascularity
8
total length
8
length calcifications
8
tendon thickness
8

Similar Publications

In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by numerous difficulties to consistently define joint coordinate frames, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation.

View Article and Find Full Text PDF

Background: Training with high-technology manikins improves cardio-pulmonary resuscitation (CPR) skill retention, but a checklist to assess both technical and non-technical skills is lacking. This study aimed to develop a standardized checklist to evaluate healthcare's performance during simulated Neonatal Resuscitation Program (NRP) scenarios.

Materials And Methods: Twenty-two international neonatal resuscitation experts participated in a two-step modified Delphi process, rating each checklist item on a scale of 1-5 and providing feedback.

View Article and Find Full Text PDF

Detecting freezing of gait: A comprehensive toolkit for enhanced Parkinson's assessment.

Parkinsonism Relat Disord

January 2025

Chulalongkorn Centre of Excellence for Parkinson's Disease & Related Disorders, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, 10330, Thailand; The Academy of Science, The Royal Society of Thailand, Bangkok, 10330, Thailand. Electronic address:

Introduction: Detecting Freezing of Gait (FOG) poses challenges, with the subjective 6-item FOG Questionnaire relying solely on patient perception. We aim to create a holistic FOG Detection Toolkit combining subjective and objective elements (descriptions, images, and videos) to improve FOG detection precision.

Methods: Development of the FOG Detection Toolkit involved a detailed cover sheet on FOG and its triggers, along with video exemplars and a 4-item FOG-specific self-assessment questionnaire, all rigorously validated.

View Article and Find Full Text PDF

Introduction: The aim was to establish EC use risk and protective factors, the reasons for use, associations with tobacco and other substance use, and use for smoking cessation.

Methods: A systematic review following PRISMA guidelines was registered in PROSPERO (CRD42024532771). Searches in Web of Science and PubMed/MEDLINE (March-April 2024) used terms like 'electronic cigarette' and 'adolescents' with a PICO framework.

View Article and Find Full Text PDF

Objective: This study evaluated the reliability and validity of the In-Out-Test for detecting episodic memory deficits in stroke patients and explored its potential as a clinical test.

Methods: A total of 75 stroke patients and 120 healthy controls underwent tests, including the Mini-Mental State Examination (MMSE), Montreal Cognitive Assessment (MoCA), Picture-Based Memory Impairment Screen (PMIS), and In-Out-Test. Reliability metrics (Cronbach's α, inter-scorer reliability, test-retest reliability), criterion validity, corrected item-total correlation, hierarchical regression analysis and ROC curve analysis were performed to determine the sensitivity and specificity of the In-Out-Test.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!